Laserfiche WebLink
x <br /> "Y <br /> _011 -,NIZ-4701-1-1- <br /> F " <br /> 1. H. KLEINFELDER &ASSOCIATES <br /> Filet 24--1045-2/27:704 <br /> December 1, 1986 <br /> Page 3 <br /> the water table. The annular space between the pipe and the wall of the <br /> boring will be backfilled with a clean sand to a minimum of two feet above <br /> the top of the perforation. A two-fcot bentonite plug would be placed <br /> above the sand pack as a seal against surface water infiltration. The <br /> remaining annulus would be backfilled with a cement-bentonite slurry to <br /> grade. The well would be placed inside a steel-locking well cover or <br /> Cristy Box to discourage vandalism, or tampering. A typical monitoring <br /> I well diagram is included at the end of this proposal. Initially one <br /> monitoring well is proposed. Based on results of soil and water sampling <br /> and screening, more wells may be required. <br /> Well DeyQlooment_and Sampling <br /> Before sampling the monitoring well should be developed to remove mud <br /> and Eines generated by drilling operations. The well would be developed <br /> by an air-lift development tool and surging. After development, the <br /> formation will be allowed to stabilize for at least one week before <br /> sampling. <br /> A water sample would be collected from the monitoring well after three <br /> to five well volumes have been removed, and parameters of temperature, pH <br /> and conductivity have s;t.abilized., JHK&A maintains a ground water sampling <br /> truck with the instrumentation, sampling and decontamination equipment <br /> necessary for the collection of an unbiased water sample. <br /> Sample A11allysia <br /> soil and water samples will be transported under chain-of-custody to a <br /> State approved testing laboratory. We recommend the soil and water <br /> samples be analyzed for total hydrocarbons (GC/FID) and benzene, toluene <br /> and xylene. Based on field screening with the PID, we recommend the <br /> sample with the highest reading from each boring be submitted for <br /> laboratory analysis. Should no organic volatiles be detected with the <br /> PTD, the deepest soil sample above the water table from each boring should <br /> be submitted to verify the absence of petroleum hydrocarbons. <br /> Report Prgparation <br /> The report will be based on the information obtained from this <br /> investigation. It should be stressed that this is a preliminary <br /> -- -- --=investigation-and that -more-soil­borings--and-monitoring wells may-be -- -. - —---- <br /> necessary to characterize this,. site. To perform this investigation we <br /> would require the following from A. Teichert & Sons, Inc. <br />