Herman&Helen 5 Marina..t Quarter 1998 Groundwater Monnormp <br /> April 16, 1998 <br /> PagL 3 <br /> 3 FIRST QUARTER, 1998, GROUNDWATER MONITORING <br /> 31 FIELD METHODOLOGY <br /> On March 27, 1998, Condor personnel were on site to conduct quarterly groundwater monitoring The monitoring <br /> included measurement of water levels in the site monitor wells and at the surface water measurement stations and <br /> the collection of groundwater samples from the monitor wells All field equipment was decontaminated in the <br /> field with a solution of laboratory-grade, non-phosphate detergent and hydrocarbon-free water and rinsed with <br /> hydrocarbon-free water prior to use in each well All field instruments were calibrated to the manufacturer's <br /> recommended standards The water level in each well was measured to the nearest 0 01 foot with a standard <br /> battery-operated, flat-tape, water-level meter A new, disposable, polyethylene barter was lowered into each well <br /> to collect a field-inspection sample The bailer sample was inspected for floating product, sheen, discoloration <br /> and/or odor Floating product was not observed in any of the monitor wells during the groundwater sampling No <br /> petroleum hydrocarbon odor was noted in any of the monitor wells <br /> EThe purging and sampling order for the monitor wells was MW-1, MW-3, MW-2, and MW-4 The wells were <br /> purged with a Grundfos Readiflo II submersible pump For the purpose of evaluating intrinsic bioremediation, <br /> various parameters were monitored during the purgmg of each well, including dissolved oxygen, reduction- <br /> oxidation potential, pll, electrical conductivity, and temperature The purge water was discharged to 55-gallon <br /> drums and left on site to await disposal Groundwater Monitoring I,reld I-orms are included to Appendix C <br /> Groundwater samples were collected by filling sample containers directly from the pump discharge tubing The <br /> groundwater was transferred to three 40-m1 glass VOA vials fitted with Teflon-Itned caps (for petroleum <br /> hydrocarbon analysis) and to a one-liter polyethylene bottle (for laboratory tested intrinsic bioremediation <br /> parameters - alkalinity, nitrate, sulfate, and ferrous iron) The vials were checked to assure that no air bubbles <br /> were present Each sample container was labeled and placed in a cooler chilled with ice and delivered under <br /> chain-of-custody procedures to GeoAnalytical Laboratories, Inc , in Modesto, California, within 24 hours of <br /> sample collection <br /> For quality control, one rinsate sample was collected and labeled 1432-MW5-3127198 The ansate sample was <br /> collected by pouring hydrocarbon-free water through the Grundfos Readiflo II submersible pump into the <br /> sampling containers after the pump was decontaminated Prior to collection of the rinsate sample, the pump was <br /> LW CONDOR <br />