My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
28983
>
2800 - Aboveground Petroleum Storage Program
>
PR0539028
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/11/2019 12:11:42 AM
Creation date
7/10/2019 4:40:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0539028
PE
2832
FACILITY_ID
FA0014411
FACILITY_NAME
CALAVERAS MATERIALS INC - Tracy RMC
STREET_NUMBER
28983
Direction
S
STREET_NAME
MACARTHUR
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25312047
CURRENT_STATUS
01
SITE_LOCATION
28983 S MACARTHUR RD
P_DISTRICT
005
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- ? r- SAN J O A Q U I N E Environmental Health Department <br /> COUNTY Mlo <br /> Greatness grows here . <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name : Facility Phone: Date: <br /> CALAVERAS MATERIALS INC - Tracy RMC (209) 585-2451 May 17 , 2019 <br /> Facility Address : CERS ID : <br /> 28983 S MACARTHUR RD , TRACY, CA 95376 10184643 <br /> Inspection Contact: Title: Phone : <br /> Andy Burgin Environmental Manager (559 ) 493-8970 <br /> Inspection Type : Program : <br /> ROUTINE INSPECTION - Operating Permit 2832 - AST FAC 10 K - </= 100 K GAL CUMULATIVE <br /> Consent For: Consent Given By: <br /> O Ins ection M Photos ❑ Sam les I Andy Burgin , Environmental Manager <br /> CCR = California Code of Regulations HSC = Health and Safety Code CFR = Title 40 Cade of Federal Regulations <br /> V = Violation R = Repeat violation COS = Corrected on site during <br /> Aboveground Petroleum Storage Act <br /> 101 HSC 25270.6(b) Failed to pay APSA program annual fees D V D R D COS <br /> 102 HSC 25270.4.5(a) Failed to prepare a written SPCC Plan in accordance with CFR Part 112 D V D R D COS <br /> 103 HSC 25270.6 (a) Failed to file HMBP or annual facility tank statement D V D R D COS <br /> 104 HSC 25270.8 Failed to report spills or releases of 42 gallons (one barrel) or more D V D R D COS <br /> 105 CFR 112. 1 (b) (3) , 112.2 Failure to properly close tanks when making a claim of permanently closed D V D R D COS <br /> 106 HSC 25404. 1 . 2 Failed to submit a certification and written response within 30 days for minor violations D V D R D COS <br /> 107 HSC 25270. 2(a) (4) Failure to prepare SPCC plan when facility no longer meets oil-filled electrical equipment exclusion D V D R D COS <br /> 108 HSC 25270.4. 5(a) Failure of conditionally exempt facility to conduct inspections or install secondary containment D V u R D COS <br /> 109 HSC 25270.2(o) (1 ) (C) Failure to have secondary containment and/or leak detection if TIUGA piping cannot be viewed D V D R D COS <br /> (iv) (111 ) <br /> 110 HSC 25404(e) (4) Failed to report program data in the California Environmental Reporting System (CERS) D V D R D COS <br /> Requirement to Prepare and Implement a SPCC Plan <br /> 201 CFR 112. 3(d) Failure to have a licensed PE properly review and certify the SPCC plan D V D R D COS <br /> 202 CFR 112 . 3(e) (1 ) Failed to maintain a copy of the Plan on site D V D R D COS <br /> 203 CFR 112. 3 Failure to implement the SPCC Plan D V D R D COS <br /> 204 CFR 112, 3 (g) Failure to prepare SPCC Plan when facility no longer meets Qualified Facility criteria D V D R D COS <br /> 205 CFR 112.32 112 . 6 Failure to prepare SPCC Plan that meets all applicable requirements D V D R D COS <br /> 206 CFR 112. 3 (d) (1 ) Failure of owner to assure that the PE makes all required attestations in the Plan D V D R D COS <br /> Amendment of SPCC Plan by Owners or Operators <br /> 301 CFR 112. 5(a) Failed to amend Plan as necessary ■ V D R D COS <br /> 302 CFR 112. 5(b) Failed to review Plan once every five years and/or implement any resulting amendments D V D R D COS <br /> 303 CFR 112. 5(c) Failed to have a PE certify technical amendments D V D R D COS <br /> 304 CFR 112.5(a) , 112. 5(b) Failure to implement SPCC plan amendments within 6 months D V D R D COS <br /> Qualified Facility - Tier 1 <br /> 401 CFR 112.6 (a) , 112.6(b) Tier I Qualified Facility Plan not certified by the owner or a PE D V D R D COS <br /> 402 CFR 112.6 (a) (2) Owner of Tier I Qualified Facility failed to self certify technical amendment D V D R D COS <br /> 403 CFR 112. 6 (a) (3)(i) Plan failed to predict direction/rate of flow/total quantity of oil potentially discharged D V D R D COS <br /> 404 CFR 112. 6(a) (3) (ii) No 2CT for bulk containers , or mobile storage containers not located to prevent discharge D V D R D COS <br /> FA0014411 PR0539028 SC001 05/17/2019 <br /> EHD 28-01 Rev. 09/27/2018 Page 1 of 6 Aboveground Petroleum Storage Act OIR <br /> 1868 E . Hazelton Avenue Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www. sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.