Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
28983
>
2800 - Aboveground Petroleum Storage Program
>
PR0539028
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/11/2019 12:11:42 AM
Creation date
7/10/2019 4:40:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0539028
PE
2832
FACILITY_ID
FA0014411
FACILITY_NAME
CALAVERAS MATERIALS INC - Tracy RMC
STREET_NUMBER
28983
Direction
S
STREET_NAME
MACARTHUR
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25312047
CURRENT_STATUS
01
SITE_LOCATION
28983 S MACARTHUR RD
P_DISTRICT
005
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DEBEnvironmental Health Department <br /> SAN JOAQUIN �q <br /> - COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address : Date: <br /> CALAVERAS MATERIALS INC - Tracy RMC 28983 S MACARTHUR RD , TRACY May 17 , 2019 <br /> Other Violations <br /> 4020 See below Unlisted Training violation ❑ V ❑ R ❑ COS <br /> 4030 See below Unlisted Operations/Maintenance violation ❑ V ❑ R ❑ COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑ V ❑ R ❑ COS <br /> 4050 See below Unlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation ❑ V ❑ R ❑ COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR - Notice to Comply) <br /> Item # Remarks <br /> 301 CFR 112 . 5(a) Failed to amend Plan as necessary. <br /> One black metal 55 gallon drum and one blue metal 55 gallon drum of motor oil were observed inside of the storage <br /> shed adjacent to the PG & E substation . The facility's SPCC plan did not include the two 55 gallon drums of motor oil . <br /> The Spill Prevention , Control , and Countermeasure (SPCC) Plan must be amended when there is a change in the <br /> facility design , construction , operation , or maintenance that materially affects its potential for a discharge , within 6 <br /> months of the change , and implemented as soon as possible , not later than 6 months following preparation of the <br /> amendment. Immediately ensure that the SPCC Plan accurately represents the inventory , procedures and policies <br /> currently in place at the facility and submit a copy to the EHD . <br /> This is a minor violation . <br /> 618 CFR 112 . 7 (e) , 112 . 8(c) (6) Failed to keep records of procedures , inspections , or integrity tests for three years . <br /> Copies of yearly inspection records for 2016 to 2019 and monthly inspections from April 2016 through October 2018 <br /> were not found on site . Inspections and tests must be conducted in accordance with the written procedures <br /> developed in the Spill Prevention , Control , and Countermeasure (SPCC) Plan . Records of these inspections and <br /> tests must be signed by the appropriate supervisor or inspector and kept on site with the SPCC Plan for a period of <br /> three years . Immediately locate a copy of all inspection and testing records for the last three years , maintain them <br /> on site , and submit copies to the EHD . <br /> This is a Class II violation . <br /> 622 CFR 112 . 7 (f) (3) Failure to conduct complete annual discharge prevention briefings for oil-handling personnel . <br /> Discharge prevention briefing records for 2018-2019 were not available for review during the inspection . The <br /> facility's SPCC plan states that discharge prevention briefing records will be kept for three years . Discharge <br /> prevention briefings for oil handling personnel must be scheduled and conducted at least once a year to assure <br /> adequate understanding of the SPCC Plan for that facility. Such briefings must highlight and describe known <br /> discharges or failures , malfunctioning components , and any recently developed precautionary measures . <br /> Immediately schedule and conduct a discharge prevention briefing , ensure that they are scheduled and conducted at <br /> least once a year and submit proof to the EHD . <br /> This is a minor violation . <br /> FA0014411 PRO539028 SC001 05/17/2019 <br /> EHD 2M1 Rev. 09/27/2018 Page 4 of 6 Aboveground Petroleum Storage Act OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www. sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.