My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
28983
>
2800 - Aboveground Petroleum Storage Program
>
PR0539028
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/11/2019 12:11:42 AM
Creation date
7/10/2019 4:40:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0539028
PE
2832
FACILITY_ID
FA0014411
FACILITY_NAME
CALAVERAS MATERIALS INC - Tracy RMC
STREET_NUMBER
28983
Direction
S
STREET_NAME
MACARTHUR
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25312047
CURRENT_STATUS
01
SITE_LOCATION
28983 S MACARTHUR RD
P_DISTRICT
005
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STI SP001 Annual Inspection Checklist <br /> General Inspection Information: <br /> Inspection Date: 6-3--10, Retain Until Date: (36 months from inspection date) <br /> Prior Inspection Date: 41/1- Inspector Name: ►' <br /> Tanks Inspected(ID#'s): 10 O00 <br /> Inspection Guidance: <br /> For equipment not included in this Standard,follow the manufacturer recommended inspection/testing schedules and procedures. <br /> ➢ The periodic AST Inspection is intended for monitoring the external AST condition and its containment structure.This visual inspection does not require a Certified <br /> Inspector. It shall be performed by an owner's inspector who is familiar with the site and can identify changes and developing problems. <br /> Remove promptly upon discovery standing water or liquid in the primary tank,secondary containment area, interstice, or spill container. Before discharge to the <br /> environment, inspect the liquid for regulated products or other contaminants and disposed of it properly. <br /> ➢ In order to comply with EPA SPCC(Spill Prevention, Control and Countermeasure)rules, a facility must regularly test liquid level sensing devices to ensure proper <br /> operation(40 CFR 112.8(c)(8)(v)). <br /> ➢ (*)designates an item in a non-conformance status.This indicates that action is required to address a problem. <br /> ➢ Non-conforming items imiportant to tank or containment integrity require evaluation by an engineer experienced in AST design,a Certified Inspector,or a tank <br /> manufacturer who will determine the corrective action. Note the non-conformance and corresponding corrective action in the comment section. <br /> ➢ Retain the completed checklists for 36 months. <br /> ➢ Complete this checklist on an annual basis supplemental to the owner monthly-performed inspection checklists. <br /> ➢ Note: If a change has occurred to the tank system or containment that may affect the SPCC plan,the condition should be evaluated against the current <br /> plan requirement by a Professional Engineer knowledgeable in SPCC development and implementation. <br /> Item Task Status Comments <br /> 1.0 Tank Containment <br /> 1.1 Containment Check for: []Yes* SiNo ❑N/A <br /> structure a Holes or cracks in <br /> containment wall <br /> or floor <br /> e Washout <br /> Liner degradation <br /> e Corrosion <br /> e Leakage <br /> e Paint failure <br /> e Tank settling <br /> 2.0 Tank Foundation and Supports <br /> 2.1 Foundation Settlement or [!Yes*_XNo <br /> foundation washout? <br /> 2.2 Concrete pad Cracking or spalling? ❑Yes* )tNo ❑N/A <br /> or ring wall <br /> AST INSPECTION STANDARD 32 SEPTEMBER 2011 <br />
The URL can be used to link to this page
Your browser does not support the video tag.