COMPLIANCE INFO 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
900
>
2300 - Underground Storage Tank Program
>
PR0231841
>
COMPLIANCE INFO 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2019 4:45:17 PM
Creation date
7/11/2019 1:28:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231841
PE
2361
FACILITY_ID
FA0000556
FACILITY_NAME
ARCO CHEROKEE GAS & MART*
STREET_NUMBER
900
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04742007
CURRENT_STATUS
01
SITE_LOCATION
900 S CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SA N J O A Q U I N Environmental Health Department <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CHEROKEE LANE SERVICE STATION' 900 S CHEROKEE LN, LODI October 29, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> The designated operator failed print out the alarm history report for the January 2018 designated operator monthly <br /> inspection report and failed to check that they were responded to appropriately. During the monthly inspection,the <br /> designated operator shall review the alarm history for the previous month, check that each alarm was documented <br /> and responded to appropriately, and attach a copy of the alarm history with documentation taken in response to any <br /> alarms to the monthly report. Ensure that designated operators performing monthly inspections at this facility are <br /> including all of the required information on the reports. <br /> This is a repeat violation, Class II. <br /> 210 CCR 2716(f) DO monthly reports not maintained on site for 12 months or for 36 months (after October 1, 2018). <br /> The September 2018,July 2018, and April 2018 designated operator monthly inspection reports were not found on <br /> site. Designated operator monthly inspection reports for the previous twelve months shall be retained on site. <br /> Locate and ensure that copies of the previous twelve months of designated operator monthly inspection reports are <br /> maintained on site. Submit copies to the EHD. <br /> This is a repeat violation, Class II. <br /> 301 HSC 25292.1(a) UST system is not operated to prevent unauthorized release, including spills and overfills. <br /> Fuel filters were observed outside of all under dispenser containments at the facility.The underground storage tank <br /> system shall be operated to prevent unauthorized releases. Immediately contact a properly licensed,trained, and <br /> certified contractor to replace or upgrade the component under permit and inspection with the EHD. <br /> This is a Class II violation. <br /> 309 CCR 2636(f)(1) Monitoring in sump/UDC failed to activate an audible and visual alarm or stop the flow product. <br /> The Bravo box float and chain in the Diesel#2 UDC sump failed to stop the flow of product at the dispenser when <br /> tested. All monitoring equipment shall be maintained to activate an audible and visual alarm or stop the flow of <br /> product at the dispenser when it detects a leak. The service technician adjusted the chain(s)and verified <br /> functionality. <br /> This is a repeat violation, Class II. <br /> 320 CCR 2635,2637.2,2665, 2712 Failure to comply with the installation, inspection, or record keeping of the overfill <br /> prevention. <br /> Owners or operators of underground storage tanks that do not meet California Code of regulations,title 23 division <br /> 3, chapter 16 section 2635(c)(2)shall test overfill prevention equipment once by October 13th, 2018 and every 36 <br /> months thereafter; and within 30 days of the date of a repair.The site did not performed the testing by October 13th, <br /> 2018. Ensure to conduct overfill prevention equipment inspection within the time frame provided by the regulation <br /> and submit test results within 30 days of performing the inspection. Ensure a 48 hour notification is provided to EHD <br /> prior to conducting the inspection. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> FA0000556 PR0231841 SCO01 10/29/2018 <br /> EHD 23-01 Rev.09/28/2018 Page 5 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sicehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.