Laserfiche WebLink
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Facility Cherokee Lane Service Station <br />Name: <br />Facility 900 S. Cherokee Ln. Lodi, CA <br />Address: <br />Da eection <br />Oct 29, 2012 <br />Facility <br />Daljit Grover/Balvinder Singh <br />M <br />Title: <br />Operator <br />br�) 334-3129 <br />Contact <br />File Review <br />101 HSC 25284 No permit to operate <br />102 HSC 25404.5 Annual operating fees not paid <br />Inspection X Routine X Monitoring System Certification D Installation D Complaint- ID#: D Other: <br />Type: <br />(Authority HSC 25289) <br />Grover/BalwinderSingh Operator <br />Consent for. X, Inspection X, Sampling XPhotos <br />Grantedby:Daljit Title: <br />Monitoring Incon TS <br />Panel: <br />Piping <br />System: <br />X Pressurized ❑ Suction ❑ Gravity <br />Overfill <br />Prevention: X Mechanical D Audible/visual <br />UST <br />6 <br />7 <br />8 <br />116 HSC 25292.5 Enhanced leak detection (ELD) testing not performed on a system located within 1000' of public well, or <br />failures not repaired and retested <br />9 <br />118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br />- - - - - - <br />- -- - - - - <br />---------- <br />------------- <br />-- - <br />Product <br />-- <br />91 -octane <br />--- <br />87 -octane <br />- -- <br />DSL <br />- <br />------------------------------ <br />87-octane <br />CCR 2650 <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight hours (M1) <br />was not recorded; (e) escaped secondary containment, not cleaned up after eight hours, or a sudden loss of <br />product was not reported to the EHD within 24 hours <br />DesignatedICC Exp. <br />Dsignated David Winkler at : <br />O Date: D <br />3-2-14 <br />Violations: D M1 -Release Detection D M2 -Release Prevention CM3 -Both <br />Site Did Winkler ICC Exp <br />avnkler <br />.3514 Manufacturer's <br />--vrni 11-10-13, incon 12-13-12 <br />Technician: Date: <br />Te <br />Training: <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = California Health and Safety Code; CCR = California Code of Regulations <br />Cl = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />File Review <br />101 HSC 25284 No permit to operate <br />102 HSC 25404.5 Annual operating fees not paid <br />103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br />monitor the tanks stem <br />104 X HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department (EHD) <br />105 X CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD (Facility and tank form) <br />106 X CCR 2632(b) Monitoring Program (Monitoring & Response Plans) is not current or approved by the EHD <br />107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br />108 CCR 2637 Secondary containment: (a) test not performed; (e) test report not submitted within 30 days; (f) test notification <br />not provided to the EHD at least 48 hours prior to conducting the test <br />Monitoring equipment certification: (a) not performed annually; (d) test report not submitted within 30 days; <br />109 X CCR 2638 (e) test notification not provided to the EHD at least 48 hours prior to conducting an installation, repair, <br />replacement calibration, or certification <br />110 HSC 25291(f) Annual line leak detector test not performed (M1) <br />111 HSC 25284.2 Annual spill containment testing not performed <br />112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (M1) <br />113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br />114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br />115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br />permit conditions <br />116 HSC 25292.5 Enhanced leak detection (ELD) testing not performed on a system located within 1000' of public well, or <br />failures not repaired and retested <br />117 CCR 2661 Permit to repair UST system not obtained <br />118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br />119 HSC 25298(b) Permit to temporarily close UST system not obtained <br />120 HSC 25298(c) Permit to close UST system not obtained <br />On Site Records <br />201 <br />CCR 2712(b) <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6'/2 years, written <br />performance claims pertaining to release detection systems for 5 years, or records of repairs, linings, and <br />upgrades for the life of the tank. Monitoring records include: (1) date and time of all monitoring or sampling; <br />(2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br />results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring <br />e ui ment, around water elevations, or other test results; 6 results of inventory readings and reconciliations <br />202 X <br />CCR 2712(i) <br />Monitoring plan, response plan, and/or operating permit and all conditions not onsite <br />203 <br />CCR 2650 <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight hours (M1) <br />was not recorded; (e) escaped secondary containment, not cleaned up after eight hours, or a sudden loss of <br />product was not reported to the EHD within 24 hours <br />Inspector Received By: Title: <br />Aris Cacapit (209) 468-345 -)(I i (- j z, w e r d rr ; ,� <br />EHD 23-02 Rev 04/19/12 Page 1 UST INSPECTION REPORT <br />