My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2011 - 2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
900
>
2300 - Underground Storage Tank Program
>
PR0231841
>
COMPLIANCE INFO 2011 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2022 1:58:23 PM
Creation date
7/12/2019 1:58:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011 - 2017
RECORD_ID
PR0231841
PE
2361
FACILITY_ID
FA0000556
FACILITY_NAME
CHEROKEE LANE SERVICE STATION*
STREET_NUMBER
900
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04742007
CURRENT_STATUS
01
SITE_LOCATION
900 S CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI RECEIVEC, <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California InA�tt� II 2 <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regufl�4MJ 12014 <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date <br />A. General Information <br />Facility Name: <br />Site Address: <br />Facility Contact Person: <br />CHEROKEE LANE SERVICE Bldg. No.: <br />ENVIRONMENTAL <br />HEALTH DEPARTMENT <br />900 S. CHEROKEE LANE City: LODI Zip: 95240 <br />Make/Model of Monitoring System: INCON TMS 550 <br />Contact Phone No.: <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced: <br />Date of Testing/Servicing: 10-29-2013 <br />Tank ID: 87 A <br />Tank Size: <br />Tank ID: 91 Tank Size: <br />® in -Tank Gauging Probe. Model: MAG <br />® In -Tank Gauging Probe. Model: MAG <br />® Annular Space or Vault Sensor. <br />Model: ULS <br />® Annular Space or Vault Sensor. Model: SAME AS 87 A <br />® Piping Sump / Trench Sensor(s). <br />Model: ULS <br />® Piping Sump / Trench Sensor(s). Model: ULS <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). Model: <br />® Mechanical Line Leak Detector. <br />Model: STP -MLD <br />® Mechanical Line Leak Detector. Model: 99 LD 2000 <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: UIL <br />Tank Size: <br />Tank ID: 87 13 Tank Size: <br />® In -Tank Gauging Probe. Model: MAG <br />® In -Tank Gauging Probe. Model: MAG <br />® Annular Space or Vault Sensor. <br />Model: ULS <br />® Annular Space or Vault Sensor. Model: SAME AS DIE <br />® Piping Sump / Trench Sensor(s). <br />Model: ULS <br />® Piping Sump / Trench Sensor(s). Model: ULS <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). Model: <br />® Mechanical Line Leak Detector. <br />Model: FX -I V -D <br />® Mechanical Line Leak Detector. Model: RJ- XL -P <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2) <br />DispenserlD: I/2 <br />Dispenser ID: 3/4 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). Model: <br />® Shear Valve(s). <br />® Shear Valve(s). <br />® Dispenser Containment Float(s) and <br />Chain(s) <br />® Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5/6 <br />Dispenser ID: 7/8 <br />❑ Dispenser Containment Sensor(s). <br />Model <br />❑ Dispenser Containment Sensor(s). Model. <br />® Shear Valve(s). <br />El Shear Valve(s). <br />® Dispenser Containment Float(s) and <br />Chain(s) <br />® Dispenser Containment Float(s) and Chain(s) <br />Dispenser ID: 9/10 <br />Dispenser ID: 9 SATELITE NOT IN SERVICE <br />❑ Dispenser Containment <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />Sensor(s). Model: <br />® Shear valve(s). <br />® Shear Valve(s). <br />® Dispenser Containment Float(s) and Chain(s) <br />® Dispenser Containment Float(s) and Chain(s). <br />'If the facility contains more tanks or dispensers, copy this form Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): ® System set-up ® Alarm history report <br />Technician Name (print): Dave Winkler Signature:1 <br />Felix Ramirez <br />Certification No.: A28446 License No: 04-1676 <br />Testing Company Name: AFFORDA-TEST Phone No. (209) 744-0113 <br />Testing Company Address: 416 2 STREET GALT, CA 95632 Date of Testing/Servicing: 10-29-12 <br />Monitoring System Certification Page 1 of 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.