My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2011 - 2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
900
>
2300 - Underground Storage Tank Program
>
PR0231841
>
COMPLIANCE INFO 2011 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2022 1:58:23 PM
Creation date
7/12/2019 1:58:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011 - 2017
RECORD_ID
PR0231841
PE
2361
FACILITY_ID
FA0000556
FACILITY_NAME
CHEROKEE LANE SERVICE STATION*
STREET_NUMBER
900
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04742007
CURRENT_STATUS
01
SITE_LOCATION
900 S CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br />Appendix VI <br />MONITORING SYSTEM CERTIFICATION JAN 2 6 2016 <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Re 06NMENTAL <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prelqMTH DEPARTMENT <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: CHEROKEE LANE ARCO Bldg. No.: <br />Site Address: <br />900 S CHEROKEE LANE City. LODI <br />Zip: 95240 <br />Facility Contact Person: DALJIT Contact Phone No.: (209) 334-3129 <br />Make/Model of Monitoring System: TS 5000 Date of Testing/Servicing: 10-12-15 <br />B. Inventory of Equipment Tested/Certified <br />Check the anorooriate boxes to indicate saecific eauioment inspected/serviced: <br />Tank ID: 87 <br />Tank ID: 87 <br />Z In -Tank Gauging Probe. <br />Model: <br />MAG <br />Z In -Tank Gauging Probe. <br />Model: <br />MAG <br />Z Annular Space or Vault Sensor. <br />Model: <br />101 <br />Z Annular Space or Vault Sensor. <br />Model: <br />101 <br />Z Piping Sump / Trench Sensor(s). <br />Model: <br />ULS <br />Z Piping Sump / Trench Sensor(s). <br />Model: <br />ULS <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />Z Mechanical Line Leak Detector. <br />Model: <br />99 LD 2000 <br />Z Mechanical Line Leak Detector. <br />Model: <br />FX1V <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />® Tank Overfill / High -Level Sensor. <br />Model: <br />FLAPPER <br />Z Tank Overfill / High -Level Sensor, <br />Model: <br />FLAPPER <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: 91 <br />TanklD DIE <br />Z In -Tank Gauging Probe. <br />Model: <br />MAG <br />Z In -Tank Gauging Probe. Model: MAG <br />Z Annular Space or Vault Sensor. <br />Model: <br />101 <br />Z Annular Space or Vault Sensor. <br />Model: <br />101 <br />Z Piping Sump / Trench Sensor(s). <br />Model: <br />ULS <br />Z Piping Sump / Trench Sensor(s). <br />Model: <br />ULS <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />Z Mechanical Line Leak Detector. <br />Model: <br />99 LD 2000 <br />Z Mechanical Line Leak Detector. <br />Model: <br />99 LD 2000 <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />Z Tank Overfill / High -Level Sensor. <br />Model: <br />FLAPPER <br />Z Tank Overfill / High -Level Sensor. <br />Model: <br />FLAPPWER <br />❑ Other (specify equipment type and <br />model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 1-2 <br />Dispenser ID: 3-4 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model <br />Z Shear Valve(s). <br />Z Shear Valve(s). <br />Z Dispenser Containment Float(s) and Chain(s). <br />® Dispenser Containment Float(s) and <br />Chain(s). <br />Dispenser ID: 5-6 <br />Dispenser ID: 7-8 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />Z Shear Valve(s). <br />Z Shear Valve(s). <br />Z Dispenser Containment Float(s) and Chain(s). <br />Z Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 9-10 <br />Dispenser ID: 11 <br />❑ Dispenser Containment <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />Sensor(s). <br />Model: <br />Z Shear Valve(s). <br />Z Shear Valve(s). <br />Z Dispenser Containment Float(s) and Chain(s). <br />Z Dispenser Containment Float(s) <br />and Chain(s). <br />`If the facility contains more tanks or dispensers. copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): ❑ System set-up ❑ Alarm history report <br />Technician Name (print): FELIX RAMIREZ Signature:s <br />Certification No.: 5273934 -UT License No: 08-1740 <br />Testing Company Name: AFFORDA-TEST Phone No. (209) 744-0113 <br />Testing Company Address: 416 2"d STREET GALT, CA 95632 Date of Testing/Servicing: 10-12-15 <br />Monitoring System Certification Page 1 of 4 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.