My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2011 - 2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
900
>
2300 - Underground Storage Tank Program
>
PR0231841
>
COMPLIANCE INFO 2011 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2022 1:58:23 PM
Creation date
7/12/2019 1:58:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011 - 2017
RECORD_ID
PR0231841
PE
2361
FACILITY_ID
FA0000556
FACILITY_NAME
CHEROKEE LANE SERVICE STATION*
STREET_NUMBER
900
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04742007
CURRENT_STATUS
01
SITE_LOCATION
900 S CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.slgov.orq/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Mattes: <br />Facility Address: <br />Date: <br />I-{Fr?()KT �,nIE SF4`.ilrr- �TpT�nnr <br />�n i nni <br />)bei -112,201r, <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />CCR 2636(0(1) Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC. <br />rle Grave box boat al a Chdin inat is In the #i,6 uuG sui-np ioi the i i pioduct, In ihu #i/ 1 uuC iur ii le diesel <br />product, and in the #1/2 UDC sump for the 87 product failed to stop the flow of product at the dispenser when tested. <br />All monitoring equipment shall be maintained to activate an audible and visual alarm or stop the flow of product at the <br />dispenser when it detects a leak. The service technician adjusted the chain(s) and verified functionality. <br />This is a repeat violation, Class II. <br />CCR 26360(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br />The 91 and 87A (12,000 gallon ._ -) VMI line leak detectors failed to detect a leak when tested. All line leak <br />detectors shall be capable of detecting a 3 -gallon per hour leak at 10 psi. The service technician adjusted the leak <br />detectors, retested them. and they passed. <br />This is a repeat violation. Class Il. <br />Overall Inspection Comments: <br />On site to conduct a routine inspection and witness the annual monitoring system certification. <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by 11-12-15. <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED ATTHE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Received By <br />Received By (printed name and title): <br />Daljit Grover & Balwinder, <br />Date: <br />h)- �'2 �S <br />(signature): <br />operato. <br />- <br />Inspector <br />Inspector (printed name and title): <br />Inspector Phone: <br />(signature): �' <br />ARIS VELOSO, Sewj REHS <br />(209) 468-3453 <br />�� Page 5 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.