Laserfiche WebLink
Vaporless I,D-2000 Addendum <br /> 4.0 Description of the Testing Location <br /> The Vaporless system was evaluated at the Fuels Management Research Center which is located <br /> in Grain Valley, Missouri and operated by Ken Wilcox Associates, Inc. All line, tests were <br /> conducted using regular unleaded gasoline. Testing for this addendum was conducted on a 200 <br /> ft. fiberglass pipeline with a volume of 85 gallons and a. 215 ft. flexible pipeline with a total <br /> volume of 19.7 gallons_ The bulk modulus was 34,443 psi for the rigid line and 4,455 psi for the <br /> flexible pipeline. <br /> The 99 LD-2000 was, installed by the manufacturer in its usual configuration in a standard Red <br /> Jacket pump. The Revd Jacket pump was installed in a 600 gallon tank where product was <br /> thermally conditioned according to the EPA protocol requirements. Product was heated or cooled <br /> in.the 600 gal Ion tank by circulating glycol and product through an external heat exchanger, Soil. <br /> temperatures were monitored by temperature sensors located at 2 inches, 4 inches and 12 inches <br /> from the line as specified by the protocol. A single temperature sensor was located 4 inches from <br /> the bottom of the product conditioning tank. The weighted soil temperature and the product tank. <br /> temperature at the beginning of the test were: used to compute the temperature differential <br /> between the soil and the product. <br /> Page 5 <br /> 6 -d 2+,C9 T 9*,602 ou I sJozoeJ 4uo0 AI az t j 3 d9*b :b0 80 �'0 noN <br />