My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1994 - 2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
900
>
2300 - Underground Storage Tank Program
>
PR0231841
>
COMPLIANCE INFO 1994 - 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/12/2019 5:29:19 PM
Creation date
7/12/2019 2:17:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1994 - 2010
RECORD_ID
PR0231841
PE
2361
FACILITY_ID
FA0000556
FACILITY_NAME
CHEROKEE LANE SERVICE STATION*
STREET_NUMBER
900
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04742007
CURRENT_STATUS
01
SITE_LOCATION
900 S CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
496
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Jan 03 07 04:19p Afrnrda Test <br />1). Results of Testing/Servicing <br />Software Version Installed. <br />i-nrruliete the following checklist: <br />(209) 744-0116 p.3 <br />Yes <br />U No" <br />Is the audible alarm operational? <br />Yes <br />Is the visual alarm operational? _ <br />U 1. No* <br />cs <br />❑ No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />yes <br />Ll No* <br />Were all scissors installed at loR•rst point of secondary containment and positioned so that other equipment will <br />not interfere with their proper operation? <br />U Ycs <br />O No* <br />If alarms are relayed to a remote monitoring station, -is all communications equipment (e.g. modem) <br />XN/A <br />operational? <br />Yes <br />U No* <br />For pressurized piping systems, docs the turbine automatically shut down if the piping secondary containment <br />❑ N/A <br />. <br />monitoring system detects a leak, fails to operit or is electrically disconnected? If ycs: which sensors utitiate <br />positive shut -down? (Check all that apply), Sump/'Trcnch Sensors; ❑ Dispenser C ztairunent Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? Yes; ❑ No. <br />❑ Ycs <br />U * <br />For tank systems that utilize the monitoring system as the primary tank overMl warning device (i.e. no <br />NIA <br />mechanical overfill prcvcntion valve is installed), is the overliIl warning alarm visible and audible at the tank <br />fill point(s) and operating properly? If so, at what percent of tank capacity docs the alarm trigger? _ _% <br />O Yes* <br />No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all rcplacementparts in Section f?, below. <br />U Yes" <br />No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that appl)) <br />U Product; U Water. If yes, describe causes in Section E, below. <br />yes- <br />❑ No* <br />Was monitoring system sct-up reviewed to ensure proper settings?. Attach set up reports, if applicable <br />❑ No* <br />Is all monitoring equiprhent operational per manufacturer's specifications? <br />cs <br />* In SCCirIon E DCIOW, aCSCrIDC /IVw All UN �AIOL\ •,.�.... .,..,..... �......... .. ... ... ....,, -- ---------- <br />E_ Comments: _ ..... <br />
The URL can be used to link to this page
Your browser does not support the video tag.