Laserfiche WebLink
--s <br /> B. Additional equipment upgrade: (see Appendix D for <br /> further information) ' <br /> 1. Protocols for upgrading: <br /> Once air monitoring data are complete and results <br /> are tabulated on the initial site entry, the Site <br /> Safety Officer and/or ';Health and Safety Manger <br /> will determine if changes in PPE are needed. <br /> 2 . Upgraded equipments <br />_. ,-,a. Respirators <br /> Respirators- with organic vapor cartridges shall be <br /> worn by a' 11 personnel #if ionization detector <br /> readings exceed 100ppm. (see page 19 for <br /> information) <br /> Note: Reference page 187 for cartridge replacement <br /> requirements. Level B must be worn when <br /> ionization detector readings exceed 750ppm and/or <br /> oxygen levels are less than 19. 5%. <br /> ' Other <br /> Tyvek suits and appropriate gloves shall be worn . <br /> if potential for dermal exposure exists while <br /> performing job tasks. <br /> C. First Aid Equipment <br /> Vehicles used for site work will be equipped with <br /> a first aid kit and safety equipment including: <br /> fluorescentvests <br /> - cones and flags <br /> - barricades <br /> - fire extinguisher <br /> flashlight <br /> 1-� - water, suitable for drinking <br /> portable ' eye wash <br /> - appropriate ;�emergency bandage material <br /> -24= <br />