Laserfiche WebLink
t <br /> APPENDIX D <br /> LEVELS OF PERSONAL PROTECTION <br /> LEVEL A <br /> F <br /> Personal Protection is required l Level A is the area where <br /> the highest levels of contamination exist and is designated <br /> as the area where maximum respiratory, skin, and eye <br /> protection are required. Aniarea may be designated as Level <br /> A when: f <br /> Atmospheres have thepotential to be Immediately. <br /> dangerous to Life and ',4Health (IDLH) . <br /> i <br /> -- Atmospheric sampling indicates (1) toxic <br /> contaminant concentrations capable of being <br /> adsorbed in toxic quantities through the eyes or <br /> skin or (2) corrosive levels that could destroy <br /> } skin surfaces. <br /> Skin contact with extremely hazardous substances <br /> (known or suspected) is possible. <br /> Egginment Ensemble: s <br /> 't s <br /> Recommended Protection Provided <br /> - P <br /> * pressure demand, full- r The highest avail- <br /> face SCBA or pressure- able level of res- <br /> demand supplied-air res,; piratory, skin, and <br /> pirator with escape SOBA eye protection <br /> * fully-encapsulating, chem <br /> ical-resistant suit. <br /> * inner chemical-resistant <br /> gloves <br /> * chemical-resistant boots/ <br /> shoes <br /> { f <br /> * hard hat <br /> .E <br /> * two-way radio communications <br /> Optional: * cooling unit' 1 <br /> * long cotton underwear <br /> * coveralls <br /> * disposable gloves and boot covers <br /> i <br /> i <br />