Laserfiche WebLink
885 Jarvis Drive <br /> Sequoia MorganHA1,CA950375037 <br /> (D (408)776 9600 <br /> iW Analytical FAX(408)782 6306 <br /> WWW scquoialahs co <br /> Secor-Rancho Cordova(ARCO) Project ARCO#4932,Stockton,CA MNA0375 <br /> 3017 Kilgore Rd Suite 100 Project Number 38984 Reported <br /> Rancho Cordova CA,95670 Project Manager Rusty Benkosky 01/28/04 16 50 <br /> Notes and Definitions <br /> HC-19 Discrete peak @ C5 <br /> HDSP The sample aliquot was taken from a VOA vial with headspace(air bubble greater than 6 mm diameter)which may have resulted in <br /> the loss of volatile analytes <br /> Q-LIM The percent recovery was outside of the control limits The samples results may still be useful for their intended purpose <br /> QR-02 The RPD result exceeded the control limits,however,both percent recoveries were acceptable Sample results for the QC batch <br /> were accepted based on percent recoveries and completeness of QC data <br /> S-LIM The surrogate recovery was outside control limits The result may still be useful for its intended purpose <br /> DET Analyte DETECTED <br /> ND Analyte NOT DETECTED at or above the reporting limit <br /> NR Not Reported <br /> dry Sample results reported on a dry weight basis <br /> RPD Relative Percent Difference <br /> • <br /> Sequoia Analytical-Morgan Hill The results rn this report apply to the samples analyzed in accardance with the chain <br /> of custody document Unless otherwise stated results are reported on a wet weight <br /> basis This analytical report must be reproduced in its entirety <br /> Page 30 of 30 <br />