My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WASHINGTON
>
2201
>
2800 - Aboveground Petroleum Storage Program
>
PR0538721
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/16/2019 9:13:32 AM
Creation date
7/23/2019 1:53:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0538721
PE
2832
FACILITY_ID
FA0009480
FACILITY_NAME
STOCKTON PORT DIST
STREET_NUMBER
2201
Direction
W
STREET_NAME
WASHINGTON
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14502004/162030
CURRENT_STATUS
01
SITE_LOCATION
2201 W WASHINGTON ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
FRuiz
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A N sJ 0 AQ U IN Environmental Health Department <br /> --CGUtVTY— <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility-a- a: eat-: <br /> STOCKTON PORT DIST 2201 W WASHINGTON ST STOCKTON Jul 15.2019 <br /> Other Violations <br /> 4010 See below Untated AdministratioraDocumentation violation ri .R .COS <br /> 4020 See below Unlisted Training violation .V .R .COS <br /> 4030 See below Unlisted OperadoneWaintenance violation o V .R o COS <br /> 4040 Sea below Unlisted Rel-ase l-im sl5pills violation .V .R o COS <br /> 4050 See below Unlisted AndridumenViregal Disposal/Unauthorized Treatment violation oV .R oCOS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLRSS 11,orMIfinance to Comply) <br /> It..# Remarks <br /> 616 CFR 112.7(e), 112.8(c)(6)Failed to keep records of procedures, inspections,or integrity tests for three years. <br /> The SPCC plan calls for annual inspections under STI SP-001 guidelines, copies of the inspections were not found on <br /> site. Inspections and tests must be conducted in accordance with the written procedures developed in the Spill <br /> Prevention, Control,and Countermeasure(SPCC)Plan. Records of these inspections and tests must be signed by <br /> the appropriate supervisor or inspector and kept on site with the SPCC Plan for a period of three years. Immediately <br /> locate a copy of all inspection and testing records for the last three years, maintain them on site, and submit copies <br /> to the EHD or provide a statement which assures the EHD that the SPCC plan will be implemented as written. <br /> This is a repeal violation, Class II. <br /> 712 CFR 112.8(c)(6)Failed to test or inspect each container for integrity based on industry standards. <br /> The tank described in the SPCC plan as a 10,000 gallon gasoline tank has not been integrity tested as per the <br /> industry standard referenced in the SPCC plan.The SPCC plan calls for an STI SID 001 pertil ed formal inspection by <br /> 2018. A STI SP-001 certified formal inspection has not been conducted. Each aboveground container shall be tested <br /> and inspected for integrity on a regular schedule. The qualifications of personnel performing tests and inspections, <br /> frequency and type of testing and inspections that take into account container size, configuration, and design shall be <br /> determined in accordance with industry standards. Examples of these integrity tests includebut are not limited to: <br /> visual Inspection,hydrostatic testing, radiographic testing, ultrasonic testing, acoustic emissions testing, or other <br /> systems of non-destructive testing. Comparison records and other records of inspections and tests must be <br /> maintained on site. Immediately conduct the necessary testing and submit a copy of the test results to the EHD,or <br /> provide equivalence as allowed by CFR 112.7(ar2). <br /> Note. The 10,000 gallon tank is described by the facility as a compartmentalized tank composed of two 5,000 gallon <br /> tanks. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certifeation form to the EHD with a statement <br /> documenting the Corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork by August 14,2019. <br /> Starting September 1,2018, all in-office CERS help will be provided at EHD hourly rate($152). To schedule an <br /> appointment, please call (209)468-3420. <br /> pedreal PRO538721 50001 071152019 <br /> EHD 2601 Rev09IPQ018 Page 4 ors ace,i unE POrcIBun Sll.,e PG OR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.