Laserfiche WebLink
' HOUSTON LABORATORY <br /> 8880 INTERCHANGE DRIVE: <br /> HOUSTON TEXAS 77054 <br /> ® (713)660 0901 <br />' Quality Control Report <br /> EXXON Company U S A <br /> TM0137 <br />�nalysis Purgeable Aromatics WorkOrder 01010025 <br /> Method SW8021 B Lab Batch ID R27105 <br />' Matrix Spike(MS)1 Matrlx_Spike Duplicate(MSD) <br /> Sample Spiked 01010025-01 <br /> Run1D HP_N_010103A-523070 Units ug/L <br />' Analysis Date 01/03/2001 17 32 Analyst DL <br /> Analyte Sample MS MS Result I MS % MSD MSD Result I MSD% RPD RPD Low High <br /> Result Spike Recovery Spike Recovery Limit Limit Limit <br /> Added Added <br /> Ienes,Total j ND 601 44 7331 60 441 7331 01 181 53 144 <br /> 1 <br /> I <br /> 1 <br />�1ers ND/U-Not Detected at the Reporting Limit MI -Matrix Interference <br /> B-Analyte detected in the associated Method Blank D-Recovery Unreportable due to Dilution <br /> J -Estimated value between MDL and PQL `-Recovery Outside Advisable QC Limits <br />'i he percent recoveries for QC samples are correct as reported Due to significant figures and 01010025 Page B <br /> rounding,the reported RPD may differ from the displayed RPD values but Is correct as reported 1/910 1 93348 AM <br /> I <br />