My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EMBARCADERO
>
6649
>
2300 - Underground Storage Tank Program
>
PR0231098
>
COMPLIANCE INFO 2012 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2020 4:45:55 PM
Creation date
7/24/2019 9:18:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2018
RECORD_ID
PR0231098
PE
2361
FACILITY_ID
FA0003830
FACILITY_NAME
VILLAGE WEST MARINA
STREET_NUMBER
6649
STREET_NAME
EMBARCADERO
STREET_TYPE
DR
City
STOCKTON
Zip
95219
APN
09815006
CURRENT_STATUS
01
SITE_LOCATION
6649 EMBARCADERO DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
388
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone. (209) 468-3420 Fax: (209) 468-3433 Web: www.sogov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />VILLAGE WEST MARINA <br />6649 EMBARCADERO DR, STOCKTON <br />March 16, 2015 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR- Notice to Comply) <br />Item # <br />Remarks <br />207 <br />CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to document all the alarms from the attached alarm history on the January 2015 <br />designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br />missing alarms include: A December 31, 2014 C 2: Diesel Annular Space Sensor Out Alarm/ Fuel Alarm were not <br />documented . During the monthly inspection, the designated operator shall review the alarm history for the previous <br />month, check that each alarm was documented and responded to appropriately, and attach a copy of the alarm <br />history with documentation taken in response to any alarms to the monthly report. Ensure that designated operators <br />performing monthly inspections at this facility are including all of the required information on the reports. This was <br />corrected on site. <br />The designated operator failed to check and note the correct test dates for the Secondary Containment test on the <br />March 2014 through February 2015 designated operator monthly inspection report. The designated operator report <br />documented the Secondary Containment test date as March 20, 2012, however the correct date on file is March 21, <br />2012. During the monthly inspection, the designated operator shall check that all required testing and maintenance <br />for the UST system have been completed and document the dates they were done. Ensure that designated operators <br />performing monthly inspections at this facility are including all of the required information on the reports. This was <br />corrected on site. <br />This is a repeat violation, Class ll. <br />306 <br />CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br />The Premium STP sump sensor was located on the wrong side and not located to detect a leak at the earliest <br />opportunity. Monitoring equipment shall be maintained to be able to detect a leak at the earliest possible opportunity. <br />The sensor was relocated to the lowest point of the sump by the service technician. Ensure that all monitoring <br />equipment is maintained to detect a leak at the earliest opportunity. This was corrected on site. <br />This is a Class II violation. <br />Overall Inspection Comments: <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />NOTES: <br />• SR0071690 and the annual Monitoring System Certification combined. <br />* Verified sensors placed at lowest point. <br />* All violations corrected on site. <br />* Secondary Containment Test due this month <br />Received by <br />Inspector: <br />Phone: <br />Date: -71 <br />(initiaq: <br />FATINAH ZAREEF, REHS <br />(209) 953-7311 <br />03/16/2015 <br />Page 4 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.