My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
1901
>
3500 - Local Oversight Program
>
PR0544688
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/24/2019 9:39:44 AM
Creation date
7/24/2019 9:31:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0544688
PE
3526
FACILITY_ID
FA0001946
FACILITY_NAME
El Dorado Food Mart
STREET_NUMBER
1901
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16508019
CURRENT_STATUS
02
SITE_LOCATION
1901 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\wng
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
211
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB . January 2002 Page 4 of 7 <br /> QUICK N ' SAVE/SOHO MARKET <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: [X ] Sump Manufacturer [ ] Indus Standard <br /> Industry [ ] Professional <br /> Engineer <br /> [ ] Other (Specify) <br /> Test Method Used : [ ] Pressure [ ] Vacuum [X ] Hydrostatic <br /> [ ] Other (Specify) <br /> Test Equipment Used : CALDWELL LEVEL GAUGE Equipment Resolution : 0.0025 <br /> Turbine Sump #1 Turbine Sump #2 <br /> Sump Diameter: 42 INCH 43 INCH <br /> Sump Depth: 391NCH 39 INCH <br /> Sump Material : FIBERGLASS FIBERGLASS <br /> Height from Tank Top to Top of 211NCH 24 INCH <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 13 INCH 10 INCH <br /> Electrical Penetration: <br /> Condition of sump prior to testing: DRY DRY <br /> Portion of Sump Tested 1 21 INCH 24 INCH <br /> Does turbine shutdown when sump [ I YES [ ] NO [ ] YES [ ) NO [ ] YES [ ] NO [ ] YES [ ) NO <br /> sensor detects liquid (both product & [X] NA [X] NA [ INA [ ] NA <br /> water)? <br /> Turbine shutdown res onse time: 5 MINUTES 5 MINUTES <br /> Is system programmed for fail-safe [ ] YES [ ] NO [ ] YES [ ] NO [ ] YES [ ] NO [ ] YES [ ] NO <br /> shutdown? [X ] NA [X INA [ INA [ INA <br /> Was fail-safe verified to be [X] YES [ ] NO [X] YES [ ] NO [ I YES [ ] NO [ ] YES [ ] NO <br /> operational? [ INA [ INA [ INA [ INA <br /> Wait time between applying 5 MIN, 5 MIN, <br /> pressure/vacuum/waterand starting <br /> test: <br /> Test Start Time: 10:30 AM 11 : 10 AM <br /> Initial Reading Rl ): 21 INCH 24 INCH <br /> Test End Time: 11 :00 AM 11 :40 AM <br /> Final Reading 21 INCH 24 INCH <br /> Test Duration: 30 MINUTES 30 MINUTES <br /> Chane in Reading Rf-RI -0- -0- -0- •0- <br /> Pass/Fail Threshold or Criteria: <br /> Test Result: [X] PASS [ I FAIL [X'] PASS [ ]TAIL _[ ] PASS [ ] FAIL [ ] PASS [ ] NO <br /> Was sensor removed for testing? [X ] YES [ ] NO [X ] YES [ ] NO [ ] YES [ ] NO [ ] YES [ ] NO <br /> NA I INA INA I INA <br /> Was sensor properly replaced and [X ] YES [ ] NO [X] YES [ ] NO [ ] YES [ ] NO [ ] YES [ I NO <br /> verified functional after testing? I [ ] N/A [ ] N/A [ ] N/A [ INA <br /> Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> 1 If the entire depth of the sump is not tested, specify how much was tested. If the answer to my of the questions indicated with an asterisk (t) is "NO" or <br /> "NA", the entire sump must be tested. (SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.