Laserfiche WebLink
Site Background Information: Quick N Save #1 <br /> Page 5 of 5 <br /> 4 is more characteristic of the aquifer (see the AGE-prepared Quarterly Report - First Quarter 2004, <br /> dated 15 June 2004) . <br /> Laboratory analysis of extracted water during the pumping test detected elevated concentrations of <br /> TPH-g, BTEX, MTBE, and 1 ,2-DCA in both samples submitted for analysis. Concentrations were <br /> as high as 61 ,000 pg/1 TPH-g, 9,900 µg/l benzene, 23 ,000 pg/I toluene, 2,500 µg/1 ethylbenzene, <br /> 183200 pg/I xylenes, 220 µg/l MTBE, and 230 gg/I 1 ,2-DCA. All concentrations detected were <br /> significantly above the respective MCLs for each contaminant. <br /> SOIL VAPOR EXTRACTION PILOT TEST <br /> On 23 August 2005, a SVE pilot test was conducted at the site. The pilot test operated for <br /> approximately 7 hours and was terminated due to stabalization. An induced vacuum potential was <br /> applied to the casing of vapor well VW-3 . The vacuum-induced pressure reduction was monitored <br /> at surrounding observation points (VW- 1 , VW-2, VW-4, and MW-2) with air-tight well caps pre- <br /> connected with Magnehelic vacuum gauges fitted to each observation well. A sample port was <br /> tapped into the PVC near the wellhead and a portable organic vapor meter equipped with a photo- <br /> ionization detector (PID: Microtip model 1000 calibrated to isobutylene) was used to measure <br /> organic vapor (OV) concentrations. The organic vapor concentrations, the induced vacuumpotential <br /> at the observation points, extracted soil gas flow rate, and revolutions per minute (RPM) of the SVE <br /> unit were measured at 0.5-hour intervals and logged on field sheets. The SVE unit was operated at <br /> approximately 2,500 RPMs for the eight-hour test, with a flow rate measured between 30 scfm <br /> (standard cubic feet per minute) and 36 scfin. OV readings ranged from 1158 to 1401 ppm. Induced <br /> vacuum measured at the extraction well (V W-3) was a constant 94 inches of water. Based upon an <br /> effective vacuum potential of 0 . 1 inches of water, the calculated effective radius of influence of SVE <br /> at the site will be approximately 28 feet. <br /> TPH-g was detected in the soil gas/vapor samples at concentrations ranging from 8,700 µg/1 to <br /> 1000 pg/1. Benzene, toluene, ethylbenzene and total xylenes were detected in the gas/vapor <br /> samples at concentrations as high as 55 µg/l of benzene, 170 pg/1 of toluene, 87 µg/1 of <br /> ethylbenzene, and 310 µg/1 of total xylenes. MTBE was detected at concentrations ranging between <br /> 120 µg/l and 160 µg/l. TPH-g, benzene, toluene, and MTBE were detected at concentrations above <br /> their respective MCLS. <br /> i <br /> Advanced GeoEnvironmenlal, Inc. <br /> III <br />