Laserfiche WebLink
' Site Background Information Quick N Save 42 <br /> AGE-NC ProjectNo 01-0815 <br /> Page 2 of 4 <br /> UNDERGROUND STORAGE TANK REMOVAL <br /> Three underground storage tanks (USTs), associated piping, and a dispenser Island were removed <br /> from the site on 06 October 1999 Seven soil samples were collected from beneath the USTs, four <br /> soil samples were collected from beneath the dispenser area,two soil samples were collected from <br /> piping trenches, and six discrete soil samples were collected from the excavated soil stockpile <br /> Methyl tertiary-butyl ether MTBE and/or tertiary butanol TBA were detected in each of the soil <br /> y (MTBE) �'Y (TBA) <br /> samples collected from the stockpiled soil Total petroleum hydrocarbons quantified as gasoline <br /> (TPH-g)were detected at concentrations as high as 2,100 milligrams per kilogram(mg/kg)beneath <br /> the eastern end of the center UST location Volatile aromatics compounds benzene, toluene, <br /> I ethylbenzene, and xylenes (BTEX) were detected at concentrations as high as 170 mg/kg from the <br /> same sample location <br /> Approximately 150 cubic yards of soil were excavated during removal of the USTs The excavated <br /> soil was stockpiled on-site <br /> INTERIM SOIL EXCAVATION <br /> On 12 May 2000, approximately 372 cubic yards of significantly petroleum hydrocarbon-Impacted <br /> soil were excavated from the former UST location Excavated soil was stockpiled on-site and <br /> covered with plastic sheeting Soil samples were collected from the base and each side wall of the <br /> I excavation at a minimum interval of one sample every 20 linear feet Samples were also collected <br /> from the stockpiled soil <br /> ITPH-g was detected in soil samples collected from the floor of the excavation at concentrations of <br /> 9 9 mg/kg(Floor S)and 4 2 mg/kg(Floor N) BTEX compounds were detected at concentrations as <br /> high as 0 67 mg/kg (xylenes) TPH-g and BTEX compounds were not detected In any of the soil <br /> samples recovered from the walls of the former UST area <br /> I MTBE was detected in sample Floor N and Floor S at concentrations of 2 3 mg/kg and 15 mg/kg, <br /> respectively, by EPA method 8260B MTBE was detected in only one soil sample recovered from <br /> the walls of the excavation area (South Wall) at a concentration of 0 000012 mg/kg <br /> Stockpile soil samples contained TPH-g at concentrations as high as 420 mg/kg,BTEX compounds <br /> were detected at concentrations as high as 30 mg/kg MTBE was detected in only one stockpile soil <br /> sample (SP 1 A-B) at a concentration of 0 25 mg/kg <br /> i <br /> I <br /> Advanced GeoEwnronmental,Inc <br /> I <br />