Laserfiche WebLink
San Joaquin County Environmental Health Department <br /> Continued HAZARDOUS WASTE GENERATOR PROGRAM INSPECTION REPORT <br /> Facility Address: Insption Date: <br /> 7 <br /> Code section VIOLATIONS <br /> 50 25160(d)HSC Transported hazardous waste without a manifest <br /> 51 25163(a)HSC Transported hazardous waste or transferred HW to a transporter without valid registration. <br /> 52 25160.2(c)(2)HSC Offered ineligible waste streams to be transported using consolidated manifest. <br /> S 5325160.2(b25x4)HSC Consolidated manifest receipts failed to contain complete information. <br /> 54 250.23 HSC Transported used oil and not registered as a hazardous waste hauler. <br /> 55 66263.17(a)CCR Transported hazardous waste without receiving ID Number and registration cert from DTSC. <br /> 56 66263.23(b)CCR Delivered hazardous waste to an unauthorized facility. <br /> 5766265.17 CCR Failed to manage incompatible waste in containers properly. <br /> 58 66265.199 CCR Failed to manage incompatible waste in tanks property. <br /> 59 25250.7 HSC Contaminated used oil with other hazardous waste. <br /> 60 1 66266.81(b)CCR Damaged lead acid batteries not properly managed and labeled. <br /> 61 66265.191(a)CCR Failed to determine if HW tank is leaking or unfit. <br /> 62 66265.191(b)CCR HW tank assessment not sufficient. <br /> Y 63 66265.191(d)CCR If HW tank found leaking or unfit,failed to comply with 66265.196. <br /> Qr67 <br /> 66265.192 CCR Failed to retain on-site required certification for HW tanks. <br /> 66265.193 CCR Failed to provide secondary containment for HW tank. <br /> 66265.194(a)CCR Placed hazardous waste or reagents in tank system that caused the tank,containment <br /> s stem or ancilla ui ment to leak,corrode,ru ture,or fail. <br /> 66265.194(b)CCR Failed to use controls and practices to prevent spillage and overflows from tank system. <br /> 66265.194(b)(3)CCR Failed to prevent overtopping from HW tank. <br /> O 66265.195(a)CCR Failed to conduct daily inspections of HW tank. <br /> ix d 70 66265.195(b)CCR Failed to inspect HW tank cathodic protection system. <br /> as 71 66265.196 CCR Failed to immediately remove tank/secondary containment system that had leaked or spilled. <br /> x 72 66265.197 CCR Tank closure,failed to remove/decon all waste and manage them as HW. <br /> 73 66265.198(au(b)CCR Failed to manage ignitable or reactive waste properly. <br /> 74 66265.199(au(b)CCR Failed to manage incompatible wastes properly. <br /> Small Quantity Handler(SQH)did not manage UW according to these sections(a}(c),[UW <br /> 75 66273.13 CCR Electronic Device(UW ED)(d):Containment(1), Notification(2),SQ Handler Standards(3), <br /> Zoning(4), Residuals(5), M mt Standards(6),Treatment Standards 7 . <br /> 76 66273.14 CCR Small Quantity Handler did not mark universal waste according to this section. <br /> 77 66273.15 CCR SQH had universal waste onsite for more than one year(a)or was unable to demonstrate the <br /> length of time UW was accumulated from the date it became a waste or was received. c <br /> y 78 66273.16 CCR SQH did not inform employees who handle UW proper handling and emergency procedures. <br /> 79 66273.32 CCR LQH did not notify the EPA RA to obtain an EPA ID#,[see UWED subsection(a)(3)(AXC)]. <br /> -j 80 66273.33 CCR Large Quantity Handler did not manage universal waste according to these sections(a)-(c) <br /> I Containment(1),Notification(2),LQ Handler Standards(3),Zoning(4),Residuals(5),Mgmt <br /> C 81 66273.33(d)CCR Standards(6),Treatment Standards(7). <br /> 82 66273.34 CCR Large Quantity Handler did not label universal waste according to this section. <br /> Z LQH had UW onsite for more than 1 year(a)or was unable to demonstrate the length of time <br /> 83 66273.35 CCR <br /> the UW has been accumulated from the date it became a waste or was received.(c) <br /> 84 66273.36 CCR LQH did not inform employees who handle UW proper handling and emergency procedures. <br /> 85 66273.39 CCR LQH did not keep records of each shipment of universal waste according to this section. <br /> 86 66273.82 CCR Cathode Ray Tube(CRT)handler accepts offsite source failed to notify DTSC 30 days prior. <br /> 87 66273.83 CCR CRT Waste Management. <br /> SQG's(generates less than 1000 kg/mo) <br /> 88 66262.34(d)CCR& Stored hazardous waste onsite greater than 180 days <br /> 25123.21(h)(1)HSC <br /> 89 66262.34(dK1)CCR Accumulated more than 6,000 kg onsite at one time. <br /> 90 66262.34(dK2)CCR Modified emergency coordinator information lacking or insufficient[as referenced by CFR <br /> 262.34(d)and CFR(e)&(0.1 <br /> OTHER <br /> 91 66261.7(f)CCR An empty HW or Haz Mat container(larger than 5 gallons)was not marked with the date it <br /> was em tied/not managed within one year of being emptied. <br /> g225217.1 HSC Liquid latex paint was disposed of,or attem ted to be disposed of,to land or water. <br /> 93 See attached"Continuation-Official Inspection Report"for violations not listed above. <br /> Spec 941 25270-25270.13 HSC I Spill Prevention Control and Countermeasure Plan not onsite for Petroleum AST's. <br /> UIC Septic System:_Serves 2:20 persons/day _Receives other than sanitary waste _Dry wells/French Drains Onsite <br /> EHD Inspector: Received Title: <br /> SO/D22-02-004 Rev 5107 600 EAST MAIN STREET,STOCKTON,CA 95202(209)468-3420 Pacts 2 <br />