Laserfiche WebLink
Western Lift-Case 2 Page 1 of 1 <br /> Nbm" �../ <br /> LTCP Checklist GO GEOTRACKER HOME I MANAGE PROJECTS I REPORTS I SEARCH IOL GOUT <br /> WESTERN LIFT-CASE 2(T10000004186)-MAP THIS SITE OPEN-ELIGIBLE FOR CLOSURE <br /> 3430 S.EL DORADO CLEANUP OV ERSIGHT AGENCIES <br /> ACTIVITIES REPORT SANJOAQUINCOLINTYLOP(LEAD)-CASE 9:2053 <br /> STOCKTON,CA 95206 CASEWORKER:VICKI MCCARTNEV-SUPERVISOR:ADRIENNE ELLSAESSER <br /> SAN JOAQUIN COUNTY PUBLICWEBPAGE CENTRAL VALLEY RWOCB(REGION5S)-CASE p:39/189 <br /> CASEWORKER:JAMES BARYON-SUPERVISOR:CORI CONDON <br /> VIEW PRINTABLE CASE SUMMARY FOR THIS SITE <br /> THIS PROJECT WAS LAST MODIFIED BY VICKI MCCARTNEY ON 5/6/2014 11:50:12 AM-HISTORY <br /> THIS SITE HAS SUBMITTALS.CLICK HERE TO OPEN A NEW WINDOW WITH THE SUBMITTAL APPROVAL PAGE FOR THIS SITE. <br /> CLOSURE POLICY THIS VERSION IS FINAL AS OF 5/6/2014 CHECKLIST INITIATED ON 611312013 CLOSURE POLICY HISTORY <br /> General Criteria-The site satisfies the policy general criteria-CLEAR SECTION ANSWERS YES <br /> a.Is the unauthorized release located within the service area of a public waters stem? <br /> C•- YES f" NO <br /> Name of Water System: JCaIWater <br /> b.The unauthorized release consists only of petroleum fiefol. G YES (' NO <br /> c.The unauthorized("primary')release from the UST system has been stopped. r YES C NO <br /> d.Free product has been removed to the maximum extent practicable Jtfgol. 0 FP Not Encountered r YES (' NO <br /> e.A conceptual site model that assesses the nature,extent,and mobility of the release has been developed jjafo. YES C NO <br /> I.Secondary source has been removed to the extent practicable ijam. (' YES (' NO <br /> g.Soil or groundwater has been tested for MTBE and results reported in accordance with Health and Safety Code Section C Not Required r YES (- NO <br /> 25296.15. <br /> h.Does a nuisance exist,as defined by Water Code section 13050. YES F NO <br /> 1.Media-Specific Criteria:Groundwater-The contaminant plume that exceeds water quality objectives is stable or decreasing in areal extent,and —YES <br /> meets all of the additional characteristics of one of the five classes of sites listed below.-CLEAR SECTION ANSWERS <br /> EXEMPTION-Soil Only Case(Release has not Affected Groundwater-Info) l" YES G NO <br /> Does the site meet any of the Groundwater specific criteria scenarios? t: YES r NO <br /> 1.1-The contaminant plume that exceeds water quality objectives is<100 feet in length.There is no free product.The nearest existing water supply well or �- YES l' NO <br /> surface water body is>250 feet from the defined plume boundary. <br /> 2.Media Specific Criteria:Petroleum Vapor Intrusion to Indoor Air-The site is considered low-threat for the vapor-intrusion-to-air pathway if site- FYES <br /> specific conditions satisfy items 2a,2b,or 2c-CLEAR SECTION ANSWERS <br /> EXEMPTION-Active Commercial Petroleum Fueling Facility ( YES r NO <br /> Does the site meet any of the Petroleum Vapor Intrusion to Indoor Air specific criteria scenarios? YES NO <br /> 215-Petroleum Vapor Intrusion to Indoor Air-A site-speck risk assessment for the vapor intrusion pathway has been prepared that demonstrates human (: YES r NO <br /> health is protected to the satisfaction of the regulatory agency. <br /> 3.Media Specific Criteria:Direct Contact and Outdoor Air Exposure-The site is considered low-threat for direct contact and outdoor air exposure YES <br /> if it meets 1,2,Or 3 below.-CLEAR SECTION ANSWERS <br /> EXEMPTION-The upper 10 feet of soil is free of petroleum contamination r YES G NO <br /> Does the site meet any of the Direct Contact and Outdoor Air Exposure criteria scenarios? r YES f' NO <br /> 3.2-A site specific risk assessment demonstrates the maximum concentrations of petroleum constituents in soil will have no significant risk of adversely (.- YES f" NO <br /> affecting human health(i.e.,'passes") <br /> Additional Information <br /> This case should be kept OPEN in spite of meeting policy criteria. YES G NO <br /> Has this LTCP Checklist been updated for FY 13114? G YES r NO <br /> SPELL CHECK <br /> Save Form as Partially Completed Save Form as Complete <br /> LOGGED IN AS MCCARTNEYV CONTACT GEOTRACKER HELP <br /> https://geotracker.waterboards.ca.gov/regulators/screens/closure—Policy.asp?global_id=T 10... 5/6/2014 <br />