Laserfiche WebLink
SPCC PLAN REGULATORY CROSS-REFERENCE TABLE <br /> Section in <br /> 40 CFR this SPCC <br /> Section Description Plan <br /> 112.7(h)Facility tank car and tank truck loading/unloading rack(excluding offshore facilities) <br /> 112.7(h)(1) Where loading/unloading area drainage does not flow into a catchment NA <br /> basin or treatment facility designed to handle discharges,use a quick <br /> drainage system for tank car or tank truck loading and unloading areas. <br /> You must design any containment system to hold at least the maximum <br /> capacity of any single compartment of a tank car or tank truck loaded or <br /> unloaded at the facility. <br /> 112.7(h)(2) Provide an interlocked warning light or physical barrier system,warning NA,similar <br /> signs,wheel chocks,or vehicle break interlock system in methods <br /> loading/unloading areas to prevent vehicles from departing before used for <br /> complete disconnection of flexible or fixed oil transfer lines. unload <br /> areas,3.6 <br /> 112.7(h)(3) Prior to filling and departure of any tank car or tank truck,closely inspect NA,similar <br /> for discharges the lowermost drain and all outlets of such vehicles,and if methods <br /> necessary,ensure that they are tightened,adjusted,or replaced to used for <br /> prevent liquid discharge while in transit. unload <br /> areas,3.6 <br /> 112.7(i) If a field-constructed aboveground container undergoes a repair, N/A <br /> alteration,reconstruction,or a change in service that might affect the risk <br /> of a discharge or failure due to brittle fracture or other catastrophe,or has <br /> discharged oil or failed due to brittle fracture failure or other catastrophe, <br /> evaluate the container for risk of discharge or failure due to brittle fracture <br /> or other catastrophe,and as necessary,take appropriate action. <br /> 112.7(j) In addition to the minimal prevention standards listed under this section, 1.0 <br /> include in your Plan a complete discussion of conformance with the 5.3.1 <br /> applicable requirements and other effective discharge prevention and <br /> containment procedures listed in this part or any applicable more stringent <br /> State rules,regulations,and guidelines. <br /> Subpart B—Requirements for Petroleum Oils and Non-Petroleum Oils,Except Animal Fats and Oils and <br /> Greases,and Fish and Marine Mammal Oils;and Vegetable Oils(Including Oils from Seeds,Nuts, <br /> Fruits,and Kernels) <br /> §112.8 Spill Prevention,Control,and Countermeasure Plan requirements for onshore facilities <br /> (excluding production facilities). <br /> 112.8(a) Meet the general requirements for the Plan listed under 40 CFR 112.7, Entire Plan <br /> and the specific discharge prevention and containment procedures listed <br /> in this section(40 CFR 112.8). <br />