My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
30703
>
2800 - Aboveground Petroleum Storage Program
>
PR0515652
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/30/2019 10:57:16 AM
Creation date
7/31/2019 1:22:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0515652
PE
2832
FACILITY_ID
FA0006475
FACILITY_NAME
TRACY MATERIAL RECOVERY/TRANSF
STREET_NUMBER
30703
Direction
S
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
25313019
CURRENT_STATUS
01
SITE_LOCATION
30703 S MACARTHUR DR
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
293
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Conclusions & Recommendations: <br /> The next recommended formal external inspection for this tank 20 years from the date of this <br /> inspection in accordance with the requirements of the EPA and CA regulations and that within <br /> the SPCC Plan, provided the following deficiencies are repaired and all required monthly and <br /> annual inspections are performed. <br /> • The fill locations on the tank should be padlocked when is <br /> • Tank A overfill plunger product return needs to be main:. <br /> • It is recommended but not required that continuous electronic monitoring with <br /> alarms for both overfills of the primary vessel and also releases into the secondary <br /> containment, be installed and made to be operational. <br /> • It is recommended but not required that on the tank, at the filling location, a flow <br /> limiting device for filling operations could be installed to minimize the danger from <br /> overfilling the primary vessel. <br /> Inspection Schedule <br /> All tank meet the requirements to listed as Category 1 as detailed in the STI Standard for <br /> Inspection of Aboveground Storage Tank SP001 Issued January 2018 6th Edition. <br /> The facility is required to perform and document US EPA, CA APSA, & San Joaquin County <br /> Environmental Health Department/Aboveground Petroleum Storage AST Monthly Visual <br /> Inspection Checklist, AST Annual Visual Inspection Checklist, and AST Tank Gauge Inspection <br /> This inspection's findings determine that the Formal External Inspection requirement should be <br /> complete and the next formal inspection-tank integrity test be completed in October 2039. <br /> Todd W. McWhorter AST-135013 10/30/19 <br /> SPCCORP Inspector Certification# Signature Date <br /> Appendix A: Supporting Photographs and drawings <br />