Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MACARTHUR
>
30703
>
2800 - Aboveground Petroleum Storage Program
>
PR0515652
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/30/2019 10:57:16 AM
Creation date
7/31/2019 1:22:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0515652
PE
2832
FACILITY_ID
FA0006475
FACILITY_NAME
TRACY MATERIAL RECOVERY/TRANSF
STREET_NUMBER
30703
Direction
S
STREET_NAME
MACARTHUR
STREET_TYPE
DR
City
TRACY
Zip
95376
APN
25313019
CURRENT_STATUS
01
SITE_LOCATION
30703 S MACARTHUR DR
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
293
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Spill Prevention Compliance Corporation <br /> Periodic Integrity Test Certificate <br /> P.O. Box 1289........Waterford, CA 95386 Telephone: (209) 969-0851 <br /> Email: spccorp aghotmail.com <br /> -------------------------------------------------------------------------------------------------------------------------------- <br /> Client: Tracy Material Recovery Contact : Kurt Duren, Compliance Manager <br /> Address: 30703 So. MacArthur Dr. Phone No.: 209-229-7605 <br /> City/State/Zip; Tracy, CA 95377 Date of Test: 10-1-2019 <br /> Product Stored: Shell Rotella T4 Triple Protection 15W-40(Tank D-upper level) UL#: No UL Plate <br /> Tank Information(Brand/gallonage/Fuel Stored/UL or other serial#/miscellaneous) <br /> Unknown/275 gals/T4 15W40/UL 80/UL#No Plate/Single Wall Steel/20 yrs old(estimated) <br /> Description of Secondary Containment Concrete Curb Impermeable Berm <br /> Date of Test-10-1-2019 Test Supervisor(s) Todd McWhorter <br /> METHOD OF PERIODIC INTEGRITY TEST-Primary XX Secondary XX <br /> 1. Steel Thickness Test(in accordance with API-653 and/or UL 80 Std.(12" Edition) Readings Steel <br /> Thickness UL 80 min. .0747in./Av2 Steel thickness =.860 in. as measured at 20 points <br /> 2. Inert Gas Blanket <br /> Gas Used: Nitrogen CO2: ; Other(specify) <br /> Air Pressure-Test Vacuum Test ; <br /> Initial Reading (document psi/WC readings) Time <br /> End Readings (document psi/WC readings) Time <br /> Duration of Test: % drop <br /> 3. Sonar-Test YN (document db readings) Duration <br /> 4. Camera(visual) model Lorex MC81845/interstitial (Result: P/F) <br /> 5. Hydro-Carbon Sensor (probe)model OMNTEC BOA- (Result: P/F) <br /> 6. Hydrology (Water Column) (inches of water column readings) <br /> Duration %Drop Results (P/F) <br /> 7. Other: Inspect Vessel& secondary containment. AST clearance is 5 inches above floor. CRDM <br /> present, no evidence of leaking product from primary vessel, system accessible for inspection: No <br /> product in secondary. Tank has Ullage electronic sensor.Upon inspection,no evidence of weld breaks, <br /> punctures,cracks,or other structural damage to the tank.Concrete Berm at upper level has 730+gals <br /> secondary containment capacity. : PASS <br /> TEST RESULTS <br /> 1St-Stage: <br /> Pass XX 'Fail_(quantify) STEEL THICKNESS OF THE WALLS & ENDS OF THE TANK <br /> WERE MEASURED AND ALL MEASUREMENTS WERE FOUND TO BE IN EXCESS OF THE <br /> MINIMUMS REQUIRED UNDER UL 80 STANDARD. <br /> 2nd-Stage: <br /> Pass XX 'Fail_(quantify) NO VISUAL EVIDENCE OF PRODUCT IN THE SECONDARY <br /> NOR OF ANY OTHER LEAKS-TANK SITS ENTIRELY WITHIN CONCRETE BERM <br /> Comments section Tank is anchored to concrete floor within berm data on file <br /> Next Scheduled Periodic Integrity Test 10-1-2024 <br /> L'�� <br /> Pacific Environmental Systems,Representative <br /> STI SP001 Certified Inspector No.: AST 135013 <br />
The URL can be used to link to this page
Your browser does not support the video tag.