Spill Prevention Compliance Corporation <br /> Periodic Integrity Test Certificate <br /> P.O. Box 1289........Waterford, CA 95386 Telephone: (209) 969-0851 <br /> Email: spccorp&hotmail.com <br /> -------------------------------------------------------------------------------------------------------------------------------- <br /> Client: Tracy Material Recovery Contact : Kurt Duren, Compliance Manager <br /> Address: 30703 So. MacArthur Dr. Phone No.: 209-229-7605 <br /> City/State/Zip; Tracy, CA 95377 Date of Test: 10-1-2019 <br /> Product Stored: Unleaded Gasoline (Dual Chamber AST 750/250 gals) UL #: 193343 <br /> Tank Information(Brand/gallonage/Fuel Stored/UL or other serial#/miscellaneous) <br /> Trusco/1000 gals/Unl. Gasoline/UL142/UL# 193343/Concrete-encased steel AST/25yrs old(estimated) <br /> Description of Secondary Containment Integral Secondary Containment <br /> Date of Test 10-1-2019 Test Supervisor(s) Todd McWhorter <br /> METHOD OF PERIODIC INTEGRITY TEST-Primary XX Secondary XX <br /> 1. Steel Thickness Test(in accordance with API-653 and/or UL 142 Std. (10th edition)-Readings Steel <br /> Thickness UL142 min. .123 in./Avg Steel thickness=.132 in. as measured <br /> 2. Inert Gas Blanket <br /> Gas Used: Nitrogen CO2: Other(specify) <br /> Air Pressure-Test Vacuum Test ; <br /> Initial Reading (document psi/WC readings) Time <br /> End Readings (document psi/WC readings) Time <br /> Duration of Test: % drop <br /> 3. Sonar-Test Y_N (document db readings) Duration <br /> 4. Camera(visual) model Lorex MC81845/interstitial (Result: P/F)_ <br /> 5. Hydro-Carbon Sensor (probe)model OMNTEC BOA- (Result: P/F) <br /> 6. Hydrology (Water Column) (inches of water column readings) <br /> Duration %Drop Results (P/F) <br /> 7. Other: Inspect Vessel& secondary containment. AST clearance is 5 inches above floor. CRDM <br /> present, no evidence of leaking product from primary vessel, system accessible for inspection: No <br /> product in secondary. Tank is as lower level fueling area. Upon inspection,no evidence of weld breaks, <br /> punctures,cracks,or other structural damage to the tank. : PASS <br /> TEST RESULTS <br /> 1St-Stage: <br /> Pass XX 'Fail_(quantify) SENSOR DETECTS NO PRODUCT , NOR LEAKS FROM PRIMARY <br /> TANK INTO SECONDARY CONTAINMENT <br /> 2°a-Stage: <br /> Pass XX Fail_(quantify) NO VISUAL EVIDENCE OF PRODUCT IN THE SECONDARY <br /> NOR OF ANY OTHER LEAKS <br /> Comments section Tank is anchored to floor data on file <br /> Next Scheduled Periodic Integrity Test 10-1-2024 <br /> L44f L— <br /> Pacific Environmental Systems,Representative <br /> STI Pacific <br /> Certified Inspector No.: AST 135013 <br />