Laserfiche WebLink
SENT BY - EMCON ASSOCIATES 9- 7-94 17 ; 02 EMCON SACRAKNTOH 12094640138 ; # 31 5 <br /> COMMONS FOR N-3218- 1-0 page; 2 <br /> 7 . At the time of initial inspection, measurements shall be taken to determine the <br /> flow ratesa influent and effluent <br /> 8. Compliance with VOC control efficiency shall be demonstrated by results of laboratory samples prior to <br /> commencing system operations. <br /> 9, The influent & effluent VOC cone, of the control device sli ill be measured at least one per month for <br /> the catalytic oxidation system & at least once per week for the carbon system, using an F13 ,PID or <br /> other District approved VOC detection device. <br /> M A log of the weekly running time and the measured influent and effluent VOC concentrations shall be <br /> maintained_ <br /> 11 . The logs shall be maintained for at least two years and made available for District inspection upon <br /> request. <br /> 12. Operation of the soil remediation system shall not exceed three years without prior District approval. <br /> 13 . The catalytic oxidizer combustion chamber temperature shall be maintained at, or above 600 degrees F. <br /> 14. Total VOC emissions from the catalytic oxidizer shall not exceed 40. 1 pounds in any one day. <br /> 19. No auxiliary fuel shall be used for the burning of gasoline vapors in the catalytic oxidizer, <br /> 16. The catalytic oxidizer shall be equipped with an operational temp, gauge to indicate the temperature of <br /> die combustion chamber_ A continuously recording device shall be utilized to indicate the combustion <br /> chamber hemp, during operation_ <br /> IT The soil remediation system shall not be operated unless the catalytic oxidizer is operating at or <br /> above the proper operating temp. An automatic shut off system shall ire utilized when the operating <br /> temp. drops below the proper operating temperature. <br /> 18. The Air Pollution Control Inspector shalt be notified in writing when the catalytic oxidizer will be <br /> modified to operate in the carbon system mode prior to the modification, <br /> 19. The carbon canister control system shall include a minimum of two carbon canisters connected in series. <br /> W. The carbon canisters removed from the system shall be sealed vapor tight. <br /> ! 1 , The effluent VOC Concentration shall not exceed 20 ppmv when utilizing the activated carbon system as <br /> the control device. <br /> 12. Neither thesoil ventilation rate nor (lie control device eluent flow shall exceed 400 cfm at any time <br /> when utilizing the activated carbon system as the control device. <br /> 13 . lAboratory samples shall be taken at locations both upstream and dowmstreant of the carbon control <br /> system and between the carbon canisters at the time of the initial use of the carbon system. <br />