Laserfiche WebLink
1 <br /> SEQUOIA ANALYTICAL <br /> 819 Striker Avenue, Suite 8 • Sacramento CA 95834 <br /> (916) 921-9600 • FAX (916) 921-0100 <br /> 1 <br /> xaris <br /> RESNA Indust V x <br /> ries Client Project ID+ #30403 ,Arco, Stockton Sampled Oct 12, 1992 <br /> 3164 Gold Camp Dr, Suite 200 Sample Matrix Air Received Oct 13, 1992 <br /> Rancho Cordova,CA 95670 Analysis Method EPA 5030/8015/8020 Reported Oct 16, 1992 <br /> Attention Matthew Taylor First Sample# 210-0314 <br /> \ �ry>♦ 1\` . <br /> TOTAL PURGEABLE PETROLEUM HYDROCARBONS with BTEX DISTINCTION <br /> Reporting Sample Sample Sample Sample Sample Sample <br /> Analyte Limit I D I D. I D. I D. I.D. I D. <br /> Mg/M3 210-0314 210-0315 210-0316 210-0317 210-0318 210-0319 <br /> 1 A1-1012-MS-1 A4-1012-ASI A1-1012-MS2 Ai-1012-MS3 A2-1012-AS1 A2-1012-MS2 <br /> Purgeable <br /> Hydrocarbons 50 4000 3400 33000 74000 6600 1800 <br /> Benzene 0 050 60 33 1200 1400 120 150 <br /> Toluene 0 050 47 38 1200 1100 89 130 <br /> Ethyl Benzene 0 050 so 56 150 36 5 6 17 <br /> Total Xyienes 0 050 16 19 670 500 49 95 <br /> Chromatogram Pattern Gas Gas Gas Gas Gas Gas <br /> r <br /> Quality Control Data <br /> Report Limit MultlDlication Factor 50 50 1 0 250 1 0 100 <br /> i <br /> Date Analyzed 10/13/92 10/13/92 10/13/92 10/13/92 10/13/92 10/14/92 <br /> Instrument Identification HP-2 HP-2 HP-2 HP-2 HP-2 HP-2 <br /> Surrogate Recovery, % <br /> (OC Limits = 70-130%) <br /> Purgeable Hydrocarbons are quantitated against a fresh gasoline standard <br /> Analytes reported as N D were not detected above the stated reporting limit <br /> 0 SEQUOIA ANALYTICAL <br /> Michael R Giles <br /> Laboratory Director <br /> 2100314 RES a 1> <br />