Laserfiche WebLink
Table 12 <br /> Summary of Analytical Results <br /> Total and Dissolved Iron,Chromium VI <br /> and PH <br /> PcBcgri Farm <br /> Well Location Sample Date Sampletl Total Fe Dissolved Fe Total Cr VI Dissolved Cr VI Curroslvity(pH) <br /> Identifications <br /> EPA 9040 <br /> UnitsP9/L /L /L /L units <br /> Lowest Drinking WQG 300 2 300 2 - 6.5-8.5 4 <br /> MCL 300 2 300 1 <br /> Wells <br /> MW-1 MW-1 12/8/2000 23000 <1 1.31 UJ <10 c10 8.03 <br /> MW-1A Du 12/8/2000 10400 <13.8 UJ <10 <10 8.23 • <br /> MW-1 1/2/2001 4,050 <8.2 <4.5 <4.5 10.38 <br /> MW-1A Du 1/2/2001 9,810 <8.2 <4.5 <4.5 10.40 <br /> MW-2 MW-2 12/8/2000 34300 <22.4 UJ <10 <10 7.22 <br /> MW-2 1/2/2001 13000 8.6 J <4.5 <4.5 723 <br /> MW-3 MW-3 12/11/2000 25,100 <67.61 UJ <10 <10 7.45 <br /> MW-3 1/2/2001 27 300 47.3 J <4.5 <4.5 7.15 <br /> MW4 MW4 12/11/2000 5840 <15.7 UJ <10 <10 701 <br /> MW4 1/2/2001 1 820 15.3 J <4.5 <4.5 10.22 <br /> MW-5 MW-5 12/11/2000 22200 <36.7 UJ <10 <10 720 <br /> MW-5 1/3/2001 11600 1 <62 <4.5 <4b 7.gg <br /> Water Supply Well - <br /> Domestic Well lDomesticWell 1/2/2001 8.41 J <8.2 -4.51 <4.5 7.33 <br /> NOTES <br /> USEPA SW-846 Test Method 6010 for Iron(Fe) <br /> USEPA SW-846 Test Method 7196 for Chromium VI(Cr VI) <br /> Lowest Drinking Water Water Quality Goal(WQG)-References provided in the Project Goals Tables(Appendix F,Table F-2A and 2B of this report). <br /> MCL-Maximum Contaminant Level(Appendix F,Table F-2A and 2B). <br /> Data Qualifiers <br /> <-Not detected at method detection limit(MDL). <br /> J-Estimated concentration between the Practical Quantitation Limit(PQL)and MDL. <br /> UJ-Estimated nondetected at the reported value due to laboratory method blank detection <br /> Page 1 of 1 2/14/2002 <br />