COMPLIANCE INFO 2015 - 2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO 2015 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 2:07:11 PM
Creation date
8/5/2019 10:44:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015 - 2016
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\M\MAIN\1399\PR0231435\2016 RETROFIT PLANS SR0074936 .PDF
QuestysFileName
2016 RETROFIT PLANS SR0074936
QuestysRecordDate
5/22/2017 9:16:03 PM
QuestysRecordID
3392977
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
307
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br />Appendix VI SEP 2 8 2016 <br />(Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.swrcb.ca.gov.) <br />MONITORING SYSTEM CERTIFICATICMVIRONMENTAL HEALTH <br />For Use By All Jurisdictions Within the State of California DEPARTMENT <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of <br />Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each monitoring <br />system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. The <br />owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: 7 -ELEVEN #19976, MKT 2368 Bldg. No.: <br />Site Address: 1399 N. MAIN ST.@ NORTHGATE <br />Facility Contact Person: BEN Contact Phone No.: 209-239-3252 <br />Make/Model of Monitoring System: Veeder Root TLS -350 <br />B. Inventory of Equipment Tested/Certified <br />Check the annrnnriate hnYes to indicate snecific enuinment inspected/sprviced: <br />City: MANTECA Zip: 95336 <br />Date of Testing/Servicing: 9/19/2016 <br />Tank ID: T4 - RUL <br />Tank ID: T5 - PUL <br />(d In -Tank Gauging Probe. Model: 846390-107 <br />r7 In -Tank Gauging Probe. Model: 846390-107 <br />I✓ Annular Space or Vault Sensor. Model: 794380-302 <br />r Annular Space or Vault Sensor. Model: 794380-302 <br />F Piping Sump / Trench Sensor(s). Model: 794380-208 <br />rv—O Piping Sump / Trench Sensor(s). Model: 794380-208 <br />W Fill Sump Sensor(s). Model: 794380-208 <br />17 Fill Sump Sensor(s). Model: 794380-208 <br />r Mechanical Line Leak Detector. Model: Vaporless LD -2000 <br />r Mechanical Line Leak Detector. Model: Vaporless LD -2000 <br />F Electronic Line Leak Detector. Model: <br />r Electronic Line Leak Detector. Model: <br />(7/ Tank Overfill / High -Level Sensor. Model: flapper <br />r%_0 Tank Overfill / High -Level Sensor. Model: flapper <br />Other(specify equipment a and model in Section E on Page 2). <br />Other(specify equipment a and model in Section E on Pa e 2). <br />Tank ID: <br />Tank ID: <br />r In -Tank Gauging Probe. Model: <br />(— In -Tank Gauging Probe. Model: <br />r Annular Space or Vault Sensor. Model: <br />r Annular Space or Vault Sensor. Model: <br />r Piping Sump / Trench Sensor(s). Model: <br />r Piping Sump / Trench Sensor(s). Model: <br />r Fill Sump Sensor(s). Model: <br />r Fill Sump Sensor(s). Model: <br />F Mechanical Line Leak Detector. Model: <br />r Mechanical Line Leak Detector. Model: <br />r Electronic Line Leak Detector. Model: <br />r Electronic Line Leak Detector. Model: <br />r Tank Overfill / High -Level Sensor. Model: <br />r Tank Overfill / High -Level Sensor. Model: <br />Other(specify equipment a and model in Section E on Page 2). <br />Other(specify equipment a and model in Section E on Pae 2). <br />Dispenser 1/2 <br />Dispenser 3/4 <br />ID: <br />ID: <br />Ii/ Dispenser Containment Sensor(s). Model: 794380-208 <br />r,70 Dispenser Containment Sensor(s). Model: 794380-208 <br />Shear Valve(s). <br />IV Shear Valve(s). <br />r Dispenser Containment Float(s) and Chain(s). <br />r Dispenser Containment Float(s) and Chain(s). <br />Dispenser <br />Dispenser <br />ID: <br />ID: <br />r Dispenser Containment Sensor(s). Model: <br />r Dispenser Containment Sensor(s). Model: <br />F Shear Valve(s). <br />r Shear Valve(s). <br />r Dispenser Containment Float(s) and Chain(s). <br />r Dispenser Containment Float(s) and Chain(s). <br />Dispenser <br />Dispenser <br />ID: <br />ID: <br />r Dispenser Containment Sensor(s). Model: <br />r Dispenser Containment Sensor(s). Model: <br />r Shear Valve(s). <br />r Shear Valve(s). <br />r Dispenser Containment Float(s) and Chain(s). <br />r Dispenser Containment Float(s) and Chain(s). <br />*It the tacility contains more tanks or dispensers, copy this torm. Include information for every tank and tllspenser at the tacillty. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. Attached to <br />this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the layout of <br />monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): IV System set- <br />up 507 Alarm history report <br />Technician Name (print): Jeffrey Crisostomo <br />Certification No.: 842876 <br />Testing Company Name: Tanknology <br />Testing Company Address: 11000 N. MoPac Expressway Suite 500 <br />Monitoring System Certification <br />Signature <br />License. No.: 743160 Ciass'A' <br />Phone No.: (800) 800-4633 <br />Page 1 of 3 <br />Date of Testing/Servicing: 9/19/2016 <br />12/07 <br />