My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2015 - 2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO 2015 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 2:07:11 PM
Creation date
8/5/2019 10:44:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015 - 2016
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\M\MAIN\1399\PR0231435\2016 RETROFIT PLANS SR0074936 .PDF
QuestysFileName
2016 RETROFIT PLANS SR0074936
QuestysRecordDate
5/22/2017 9:16:03 PM
QuestysRecordID
3392977
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
307
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GROSS TEST FAIL <br />ALARM DISABLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIFY: OFF <br />TNK TST SIPHON BREAKOFF <br />DELIVERY DELAY 3 MIN <br />PUMP THRESHOLD 10.00% <br />LEAK TEST METHOD <br />TEST ON DATE : ALL TANK <br />FEB 6, 2007 <br />START TIME : DISABLED <br />TEST RATE :0.20 GAL/HR <br />DURATION : 2 HOURS <br />TST EARLY STOP:DISABLED <br />LEAK TEST REPORT FORMAT <br />NORMAL <br />LIQUID SENSOR SETUP <br />L 1:RUL ANNULAR <br />DUAL POINT HYDROSTATIC <br />CATEGORY : ANNULAR SPACE <br />L 2:RUL STP SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 3:PREMIUM ANNULAR <br />DUAL POINT HYDROSTATIC: <br />CATEGORY : ANNULAR SPACE <br />L 4:PREMIUM STP SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 5:RUL FILL SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : PIPING SUMP <br />L 6:PREM FILL SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : P IPI 14G SUMP <br />11 <br />L 7:DISP 1-2 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L 8:DISP 3-4 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />RECEIVED <br />SEP 2 8 2016 <br />ENVIRONMENTAL HEALTH <br />OUTPUTAR�TMENT <br />R 1:RUL F.S.D. <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />TANK 0: 4 <br />LIQUID SENSOR ALMS <br />L 2:FUEL ALARM <br />L ?:FUEL ALARM <br />L B:FUEL ALARM <br />L 2:SENSOR OUT ALARM <br />L 7:SENSOR OUT ALARM <br />L B:SENSOR OUT ALARM <br />L 2:SHORT ALARM <br />L 7:SHORT ALARM <br />L 8:SHORT ALARM <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />R 2:PUL P.S.D. <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />TANK 0: 5 <br />LIQUID SENSOR ALMS <br />L 4:FUEL ALARM <br />L 7:FUEL ALARM <br />L B:FUEL ALARM <br />L 4:SENSOR OUT ALARM <br />L 7:SENSOR OUT ALARM <br />L B:SENSOR OUT ALARM <br />L 4:SHORT ALARM <br />L 7:SHORT ALARM <br />L B:SHORT ALARM <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL. <br />RECONCILIATION SETUP <br />EDIM 1: <br />EDIM 2: <br />AUTOMATIC DAILY CLOSING^ <br />TIME: 2:00 AM <br />AUTO SHIFT #1 CLOSING <br />TIME: DISABLED <br />AUTO SHIFT 02 CLOSING <br />TIME: DISABLED <br />AUTO SHIFT 03 CLOSING <br />TIME: DISABLED <br />AUTO SHIFT 94 CLOSING <br />TIME: 6:00 AM <br />PERIODIC RECONCILIATION <br />MODE: <br />MONTHLY <br />ALARM: <br />DISABLED <br />TEMP COMPENSATION <br />STANDARD <br />METER CALIBRATION <br />OFFSET: <br />0.000°% <br />BUS SLOT <br />FUEL METER <br />TANK <br />3 2 <br />1 <br />2 <br />4 <br />3 2 <br />1 <br />3 <br />5 <br />3 2 <br />2 <br />2 <br />4 <br />3 2 <br />2 <br />3 <br />5 <br />3 2 <br />3 <br />2 <br />4 <br />3 2 <br />3 <br />3 <br />5 <br />3 2 <br />4 <br />2 <br />4 <br />3 2 <br />4 <br />3 <br />5 <br />SMARTSENSOR SETUP <br />s 1:DISP 1-2 AFM <br />CATEGORY AIR FLOW METER <br />s 2:DISP 3-4 AFM <br />CATEGORY AIR FLOW METER <br />s 3:3-4 VAPOR PRESSURE <br />CATEGORY VAPOR PRESSURE <br />