Laserfiche WebLink
RECEIVED <br /> Appendix VI n11/ �0,4 <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.s J l�C <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California ENVIRONMENTAL HEALTH <br /> Authority Cited:Chapter 6.7, Health and Safety Code;Chapter 16, Division 3, Title 23, CaliPWk& T <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: 7-ELEVEN#19976,MKT 2368 Bldg. No.: <br /> Site Address: 1399 N. MAIN ST.@ NORTHGATE City: MANTECA Zip: 95336 <br /> Facility Contact Person: BEN Contact Phone No.: 209-239-3252 <br /> Make/Model of Monitoring System: Veeder Root TLS 350 Date of Testing/Servicing: 10/13/2014 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment ins ected serviced: <br /> Tank ID: T4-RUL Tank ID: T5-PUL <br /> W In-Tank Gauging Probe. Model: mag rV In-Tank Gauging Probe. Model: mag <br /> Annular Space or Vault Sensor. Model: 303 r1_1 Annular Space or Vault Sensor. Model: 303 <br /> 17 Piping Sump/Trench Sensor(s). Model: 208 r Piping Sump/Trench Sensor(s). Model: 208 <br /> r7 Fill Sump Sensor(s). Model: 208 ry-1 Fill Sump Sensor(s). Model: 208 <br /> Mechanical Line Leak Detector. Model: Vaporless LD-2000 r Mechanical Line Leak Detector. Model: Vaporless LD-2000 <br /> r Electronic Line Leak Detector. Model r Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor.Model: flapper W Tank Overfill/High-Level Sensor.Model: flapper <br /> Other(specify equipment a and model in Section E on Pae 2). Other(specify equipment a and model in Section E on Pae 2). <br /> Tank ID: Tank ID: <br /> In-Tank Gauging Probe. Model: r In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: r Annular Space or Vault Sensor. Model: <br /> r Piping Sump/Trench Sensor(s). Model: r Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: r- Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: r Mechanical Line Leak Detector. Model: <br /> r Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> r Tank Overfill/High-Level Sensor.Model: r Tank Overfill/High-Level Sensor.Model: <br /> Other(specify equipment a and model in Section E on Pae 2). Other(specify equipment a and model in Section E on Pae 2). <br /> Dispenser 1/2 Dispenser 3/4 <br /> ID: ID: <br /> R Dispenser Containment Sensor(s).Model: 208 r Dispenser Containment Sensor(s).Model: 208 <br /> d/ Shear Valve(s). r Shear Valve(s). <br /> I— Dispenser Containment Float(s)and Chain(s). r— Dispenser Containment Float(s)and Chain(s). <br /> Dispenser Dispenser <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: (� Dispenser Containment Sensor(s).Model: <br /> r Shear Valve(s). r Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser Dispenser <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: Dispenser Containment Sensor(s).Model: <br /> r Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines.Attached to <br /> this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply):PO System set- <br /> up P Alarm history report <br /> Technician Name(print): Jarrod Cooke Signature: - <br /> Certification No.: B35255 License. No.: 743160 Class'A' <br /> Testing Company Name: Tanknology Phone No.: (800)800-4633 <br /> Testing Company Address: 11000 N.MoPac Expressway Suite 500 Date of Testing/Servicing: 10/13/2014 <br /> Monitoring System Certification Page 1 of 3 12/07 <br />