My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2014
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO 2010 - 2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/5/2019 3:37:10 PM
Creation date
8/5/2019 11:56:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2014
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
434
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GROSS TEST FAIL <br /> • T 5:PREMIUM ALARM DISABLED <br /> PRODUCT CODE 5 <br /> THERMAL COEFF : .000690 ANN TEST AVERAGING: OFF L 8:DISP 3-4 <br /> TANK DIAMETER 89.75 PER TEST AVERAGING: OFF /k TRI-STATE (SINGLE FLOAT) <br /> TANK PROFILE 20 PTS / ATEGORY DISPENSER PAN <br /> FULL VOL 9684 TANK TEST NOTIFY: OFF <br /> 85.3 INCH VOL 9524 <br /> 80.8 INCH VOL 9226 TNK TST SIPHON BREAKOFF <br /> 76.3 INCH VOL 8850 <br /> 71 .8 INCH VOL 8484 DELIVERY DELAY 3 MIN <br /> 67.3 INCH VOL 7891 PUMP THRESHOLD 10.00% <br /> 62.8 INCH VOL 7326 <br /> 58.3 INCH VOL 6760 <br /> 53.8 INCH VOL 6138 <br /> 49.4 INCH VOL 5551 <br /> 44.9 INCH VOL 4904 <br /> 40.4 INCH VOL 4273 <br /> 35.9 INCH VOL 3667 <br /> 31 .4 INCH VOL 3040 OUTPUT RELAY SETUP <br /> 26.9 INCH VOL 2470 - - - - - - - - - - - - <br /> 22.4 INCH VOL 1913 <br /> 17.9 INCH VOL 1396 R 1 :RUL P.S.D. <br /> 13.5 INCH VOL 930 TYPE: <br /> 9.0 INCH VOL 528 LEAK TEST METHOD STANDARD <br /> 4.5 INCH VOL 210 - - - - - - - - - - - - NORMALLY CLOSED <br /> METER DATA YES TEST ON DATE : ALL TANK <br /> END FACTOR: HEMISPHER FEB 6, 2007 TANK #: 4 <br /> CAL UPDATE: NEVER START TIME : DISABLED <br /> TEST RATE :0.20 GAL/HR <br /> DURATION 2 HOURS LIQUID SENSOR ALMS <br /> FLOAT SIZE: 4.0 IN. L 2:FUEL ALARM <br /> WATER MINIMUM 0.000 TST EARLY STOP:DISABLED L 7:FUEL ALARM <br /> L 8:FUEL ALARM <br /> WATER WARNING 1 .0 LEAK TEST REPORT FORMAT L 2:SENSOR OUT ALARM <br /> HIGH WATER LIMIT: 1 .5 NORMAL L 7:SENSOR OUT ALARM <br /> WATER ALARM FILTER: LOW L 8:SENSOR OUT ALARM <br /> L 2:SHORT ALARM <br /> L 7:SHORT ALARM <br /> MAX OR LABEL L 8:SHORT ALARM <br /> VOLUME 9684 <br /> ISD SITE ALARMS <br /> HIGH PRODUCT ISD GROSS PRES FAIL <br /> % MAX : 95.0 ISD DEGRD PRES FAIL <br /> (GALLONS) ISD VAPOR LEAK FAIL <br /> OVERFILL LIMIT ISD HOSE ALARMS <br /> % MAX 90.0 LIQUID SENSOR SETUP ALL:GROSS COLLECT FAIL <br /> (GALLONS) 8716 - - - - - - - - - - - - ALL:DEGRD COLLECT FAIL <br /> ALL:FLOW COLLECT FAIL <br /> DELIVERY LIMIT L 1 :RUL ANNULAR <br /> % MAX 10.0 UAL POINT HYDROSTATIC R 2:PUL P.S.D. <br /> (GALLONS) 968 •ATEGORY : ANNULAR SPACE TYPE: <br /> STANDARD <br /> LOW PRODUCT NORMALLY CLOSED <br /> VOLUME 742 <br /> L 2:RUL STP SUMP TANK #: 5 <br /> LEAK ALARM LIMIT: 15 TRI-STATE (SINGLE FLOAT) <br /> SUDDEN LOSS LIMIT: 25 CATEGORY : STP SUMP <br /> TANK TILT 0.00 LIQUID SENSOR ALMS <br /> PROBE OFFSET 0.00 L 4:FUEL ALARM <br /> L 3:PREMIUM ANNULAR L 7:FUEL ALARM <br /> UAL POINT HYDROSTATIC L 8:FUEL ALARM <br /> SIPHON MANIFOLDED TANKS �ATEGORY : ANNULAR SPACE L 4:SENSOR OUT ALARM <br /> T#: NONE L 7:SENSOR OUT ALARM <br /> LINE MANIFOLDED TANKS L R:SENSOR OUT ALARM <br /> T#: NONE L 4:SHORT ALARM <br /> CEGORY <br /> :PREMIUM STP SUMP L 7:SHORT ALARM <br /> -STATE (SINGLE FLOAT) L 8:SHORT ALARM <br /> LEAK 1°1 I N PERIODIC: 0% : STP SUMP <br /> 0 ISD SITE ALARMS <br /> ISD GROSS PRES FAIL <br /> LEAK P,1I1'-J ANNUAL 0% L 5:RUL FILL SUMP ISD DEGRD PRES FAIL <br /> • 0 TRI-STATE (SINGLE FLOAT) ISD VAPOR LEAK FAIL <br /> ,, CATEGORY : PIPING SUMP <br /> ISD HOSE ALARMS <br /> PERIODIC TEST TYPE ALL:GROSS COLLECT FAIL <br /> STANDARD L 6:PREM FILL SUMP ALL:DEGRD COLLECT FAIL <br /> -TRI-STATE (SINGLE FLOAT) ALL:FLOW COLLECT FAIL <br /> ANNUAL TEST FAIL ^CATEGORY : PIPING SUMP <br /> ALARM DISABLED <br /> PERIODIC TEST FAILL 7:DISP 1-2 <br /> ALARM DISABLED TRI-STATE (SINGLE FLOAT) <br /> _ <br /> ATEGORY : DISPENSER PAN <br />
The URL can be used to link to this page
Your browser does not support the video tag.