Laserfiche WebLink
SYMEM SET-UP REPORT <br />SYSTEM SETUP <br />JAN 22, 2009 8:50 AM <br />SYSTEM UNITS <br />U.S. <br />SYSTEM LANGUAGE <br />ENGLISH <br />SYSTEM DATE./TIME FORMAT <br />MON DD YYYY HH:MM:SS xM <br />235090 7-11 19976 <br />1399 N. MAIN ST. <br />MANTECA-CA. 95336 <br />A036903405001 <br />SHIFT TIME 1 7:00 AM <br />SHIFT TIME 2 DISABLED <br />SHIFT TIME 3 DISABLED <br />SHIFT TIME 4 DISABLED <br />SHIFT BIR PRINTOUTS <br />DISABLED <br />DAILY BIR PRINTOUTS <br />DISABLED <br />TICKETED DELIVER`! <br />DISABLED <br />TANK PER TST NEEDED WRN <br />DISABLED <br />TANK ANN TST NEEDED WRN <br />DISABLED <br />LINE RE -ENABLE METHOD <br />PASS LINE TEST <br />LINE PER TST NEEDED WRN <br />DISABLED <br />LINE ANN TST NEEDED WRN <br />DISABLED <br />PRINT TC VOLUMES <br />ENABLED <br />TEMP COMPENSATION <br />VALUE (DEG F ): 60.0 <br />STICK HEIGHT OFFSET <br />DISABLED <br />ULLAGE: 90% <br />H -PROTOCOL DATA FORMAT <br />HEIGHT <br />DAYLIGHT SAVING TIME <br />ENABLED <br />START DATE <br />MAR WEEK 2 SUN <br />START TIME <br />2:00 AM <br />END DATE <br />NOV WEER: 1 SUN <br />END TIME <br />2:00 AM <br />C�) 2006 Walton Engineering, Inc. <br />0I^MMUN I CAT I ONS SETUP <br />PORT SETTINGS: <br />COMM BOARD : 1 (EDIM ) <br />RS -232 SECURITY <br />CODE : DISABLED <br />COMM BOARD : 2 (EDIM > <br />RS -232 SECURITY <br />CODE : DISABLED <br />COMM BOARD 3 (S -SAT <br />BAUD RATE 9600 <br />PARITY NONE <br />STOP BIT 1 STOP <br />DATA LENGTH: 8 DATA <br />RS -232 SECURITY <br />CODE : DISABLED <br />DTR NORMAL STATE: HIGH <br />COMM BOARD 5 (RS -485) <br />BAUD RATE 2400 <br />PARITY : EVEN <br />STOP BIT 1 STOP <br />DATA LENGTH: 7 DHTA <br />RS -232 SECURITY <br />CODE : DISABLED <br />COMM BOARD 6 (RS -232) <br />BAUD RATE 1200 <br />PARITY ODD <br />STOP BIT 1 STOP <br />DATA LENGTH: 7 DATA <br />RS -232 SECURITY <br />CODE : DISABLED <br />AUTO TRANSMIT SETTINGS: <br />AUTO LEAK ALARM LIMIT <br />DISABLED <br />AUTO HIGH WATER LIMIT <br />DISABLED <br />AUTO OVERFILL LIMIT <br />DISABLED <br />AUTO LOW PRODUCT <br />DISABLED <br />AUTO THEFT LIMIT <br />DISABLED <br />AUTO DELIVERY START <br />DISABLED <br />AUTO DELIVERY END <br />DISABLED <br />AUTO EXTERNAL INPUT ON <br />DISABLED <br />AUTO EXTERNAL INPUT OFF <br />DISABLED <br />AUTO SENSOR FUEL ALARM <br />DISABLED <br />AUTO SENSOR WATER ALARM <br />DISABLED <br />AUTO SENSOR OUT ALARM <br />DISABLED <br />tPage 1) <br />AUTO DIAL TIME SETUP: <br />D 5 : Fri FMS <br />DIAL MONTHLY <br />WEEK 1 THR <br />DIAL TIME : 12:25 PM <br />RECEIVER REPORTS: <br />D B:VEEDER-ROOT FMS <br />DIAL MONTHLY <br />WEEK 1 THR <br />DIAL TIME : 12:25 PM <br />RECEIVER REPORTS: <br />RECEIVER SETUP: <br />D 5 : F61 FMS <br />C10.90.3.96-3001 <br />RCVR TYPE: COMPUTER <br />PORT NO: 3 <br />RETRY NO: 5 <br />RETRY DELAY: 5 <br />CONFIRMATION REPORT: ON <br />D 8:VEEDER-ROOT FMS <br />C3 <br />RCVR TYPE: COMPUTER <br />PORT NO: 3 <br />RETRY NO: 5 <br />RETRY DELAY: 5 <br />CONFIRMATION REPORT: OFF <br />RS -232 END OF MESSAGE <br />DISABLED <br />AUTO DIAL ALARM SETUP <br />D 5 : Fid FMS <br />IN -TANK ALARMS <br />ALL:LEAK ALARM <br />ALL:HIGH WATER ALARM <br />ALL:OVERFILL ALARM <br />T I:LOW PRODUCT ALARM <br />ALL:SUDDEN LOSS ALARM <br />ALL:HIGH PRODUCT ALARM <br />ALL:INVALID FUEL LEVEL <br />ALL:PROBE OUT <br />ALL:HIGH WATER WHRNING <br />ALL:DELIVERY NEEDED <br />ALL:MAX PRODUCT ALARM <br />ALL:GROSS TEST FAIL <br />ALL:PERIODIC TEST FAIL <br />ALL:ANNUAL TEST FAIL <br />ALL:PER TST NEEDED WRN <br />ALL:ANN TST NEEDED WRN <br />ALL:PER TST NEEDED ALM <br />ALL:ANN TST NEEDED ALM <br />T 1:TANK TEST ACTIVE <br />ALL:NO CSLD IDLE TIME <br />ALL:TANK SIPHON BREAK <br />ALL:CSLD INCR RATE WARN <br />ALL:ACCUCHART CAL WARN <br />ALL:RECON WARNING <br />ALL:RECON ALARM <br />ALL:LOW TEMP WARNING <br />ALL:MISSING TICKET WARN <br />T 1:GROSS FAIL LINE TNK <br />ALL:DELIVY DENSITY WARN <br />