Laserfiche WebLink
SYMEM SET-UP REPORT kPage3) <br />IN -TANK SETUP <br />T 1:UNLEADED <br />2 <br />PRODUCT CODE <br />1 <br />THERMAL COEFF <br />:.000700 <br />TANK DIAMETER <br />90.38 <br />TANK PROFILE <br />1 PT <br />FULL VOL <br />14781 <br />METER DATA <br />YES <br />END FACTOR: <br />NONE <br />CAL UPDATE: NEVER <br />FLOAT SIZE: 4.0 <br />WATER WARNING 1.0 <br />HIGH WATER LIMIT: 1.5 <br />MAX OR LABEL VOL: 14781 <br />OVERFILL LIMIT 90%6 <br />13303 <br />HIGH PRODUCT 90% <br />13303 <br />DELIVERY LIMIT 10%6 <br />1478 <br />LOW PRODUCT 997 <br />LEAK ALARM LIMIT: 99 <br />SUDDEN LOSS LIMIT: 99 <br />TANK TILT 0.00 <br />PROBE OFFSET 0.00 <br />SIPHON MANIFOLDED TANKS <br />TO: NONE <br />LINE MANIFOLDED TANKS <br />TO: NONE <br />LEAK MIN PERIODIC: 0% <br />0 <br />LEAK MIN ANNUAL : 0'. <br />0 <br />T 2:PREMIUM <br />PRODUCT CODE <br />2 <br />THERMAL COEFF <br />:.000700 <br />THNK DIAMETER <br />89.75 <br />TANK PROFILE <br />1 PT <br />FULL VOL <br />9684 <br />METER DATA <br />YES <br />END FACTOR: <br />NONE <br />CAL UPDATE: NEVER <br />FLOAT SIZE: 4.0 IN. <br />WATER WARNING I.0 <br />HIGH WATER LIMIT: 1.5 <br />MAX OR LABEL VOL: 9684 <br />OVERFILL LIMIT 90% <br />8715 <br />HIGH PRODUCT 90% <br />8715 <br />DELIVERY LIMIT 10/0 <br />968 <br />LOW PRODUCT 742 <br />LEAK ALARM LIMIT: 99 <br />SUDDEN LOSS LIMIT: 99 <br />TANK TILT 0.00 <br />PROBE OFFSET 0.00 <br />SIPHON MANIFOLDED TANKS <br />TO: NONE <br />LINE MHNIFOLDED TANKS <br />TO: NONE <br />LEAK MIN PERIODIC: 0% <br />0 <br />LEAK MIN ANNUAL 0% <br />0 <br />PERIODIC TEST TYPE PERIODIC TEST TYPE <br />STANDARD STANDARD <br />ANNUAL TEST FAIL <br />ALARM DISABLED <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />GROSS TEST FAIL <br />ALARM DISABLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIFY: OFF <br />TNK TST SIPHON BREAKOFF <br />DELIVERY DELAY 3 MIN <br />PUMP THRESHOLD 10.00% <br />fc) 2006 Walton Engineering, Inc. <br />ANNUAL TEST FAIL <br />ALARM DISABLED <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />GROSS TEST FAIL <br />ALARM DISABLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIFY: OFF <br />TNK TST SIPHON BREAKOFF <br />DELIVERY DELAY 3 MIN <br />PUMP THRESHOLD 10.00 <br />LEAK TEST METHOD <br />TEST ON DATE : ALL TANK <br />FEB 6. 2007 <br />START TIME : DISABLED <br />TEST RATE :0.20 GAL/HR <br />DURATION : 2 HOURS <br />TST EARLY STOP:DISABLED <br />LEAK TEST REPORT FORMAT <br />NORMAL <br />LIQUID SENSOR SETUP <br />L I:RUL ANNULAR <br />DUAL POINT HYDROSTATIC <br />CATEGORY : ANNULAR SPACE <br />L 2:RUL STP SUMP <br />TRI-STATE (SINGLE FLOAT: <br />CATEGORY : STP SUMP <br />L 3:PREMIUM ANNULAR <br />DUAL POINT HYDROSTATIC <br />CATEGORY : ANNULAR SPACE <br />L 4:PREMIUM STP SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 5:RUL FILL SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : PIPING SUMP <br />L 6:PREM FILL SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : PIPING SUMP <br />L 7:DISP 1-2 <br />TRI-STATE (SINGLE FLOAT) <br />CHTEGORY : DISPENSER PAN <br />L 8:DISP 3-4 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />