My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2005 - 2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231435
>
COMPLIANCE INFO 2005 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/7/2019 3:13:32 AM
Creation date
8/6/2019 2:20:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005 - 2009
RECORD_ID
PR0231435
PE
2361
FACILITY_ID
FA0000916
FACILITY_NAME
7-ELEVEN INC #19976
STREET_NUMBER
1399
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
21633034
CURRENT_STATUS
01
SITE_LOCATION
1399 N MAIN ST
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
344
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITq#ING SYSTEM CERTIF"FATION <br />MAKE / MODEL OF MONITORING SYSTEM: <br />CERTIFICATION /TEST DATE: December 26, 2007 <br />Al. FACILITY <br />A2. OWNER <br />Name 7 -Eleven Market #2237 / Store #19976 <br />Name 7 -Eleven, Inc <br />Address 1399 N. Main Street, Manteca, CA 95336 <br />Address P.O. Box 711, Dallas, TX 75221 <br />Phone# 209-239-3252 <br />Phone# 805-523-2949 <br />Contact Shane Partridge <br />Contact Shane Partridge <br />A3. C UP A <br />A4. TESTING CONTRACTOR <br />Name San Joaquin County Environmental Health <br />Name Walton Engineering, Inc. <br />Address 600 E. Main Street , Stockton, CA 95202 <br />Address P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified December 21, 2007 <br />Lic # 617238 A, B, Haz <br />Inspector Muniappa Naidu <br />Contact Richard Walton <br />Phone# 209-468-3439 <br />Phone# 916-825-3203 <br />B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check <br />the appropriate boxes to indicate equipment inspected/serviced) <br />131: <br />TANKS <br />Tank #4 (Product): Gasoline - 87 <br />❑ In -Tank Gauging Probe Model: <br />❑ In -Tank Gauging Probe Model: <br />❑ Annular Space or Vault Sensor Model: <br />❑ Annular Space or Vault Sensor Model: <br />❑ Piping Sump I Trench Sensor(s) Model: <br />❑ Piping Sump / Trench Sensor(s) Model: <br />❑ Fill Sump Sensor(s) Model: <br />❑ Fill Sump Sensor(s) Model: <br />■ Mechanical Line Leak Detector Model: Vaporless 99LD-2000 <br />❑ Mechanical Line Leak Detector Model: <br />❑ Electronic Line Leak Detector Model: <br />❑ Electronic Line Leak Detector Model: <br />❑ Tank Overfill / High -Level Sensor Model: <br />❑ Tank Overfill / High -Level Sensor Model: <br />❑ Other (specify equipment in Section E) Model: <br />❑ Other (specify equipment in Section E) Model: <br />❑ In -Tank Gauging Probe Model: <br />❑ In -Tank Gauging Probe Model: <br />❑ Annular Space or Vault Sensor Model: <br />❑ Annular Space or Vault Sensor Model: <br />❑ Piping Sump / Trench Sensor(s) Model: <br />❑ Piping Sump I Trench Sensor(s) Model: <br />❑ Fill Sump Sensor(s) Model: <br />❑ Fill Sump Sensor(s) Model: <br />❑ Mechanical Line Leak Detector Model: <br />❑ Mechanical Line Leak Detector Model: <br />❑ Electronic Line Leak Detector Model: <br />❑ Electronic Line Leak Detector Model: <br />❑ Tank Overfill / High -Level Sensor Model: <br />❑ Tank Overfill I High -Level Sensor Model: <br />❑ Other (specify equipment in Section E) Model: <br />❑ Other (specify equipment in Section E) Model: <br />62: DISPENSERS/UDC's <br />Dispenser # : Dispenser # <br />❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Valves ❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) ❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : Dispenser # <br />❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Valves ❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) ❑ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : Dispenser # <br />❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br />❑ Shear Valves ❑ Shear Valves <br />❑ Dispenser Containment Float(s) and Chain(s) ❑ Dispenser Containment Float(s) and Chain(s) <br />C. CERTIFICATION I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the <br />layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a copy of the report; (check all that apply): <br />❑ System set-up ❑ Alarm History Report <br />� � yWALTON - <br />+.J/K/y <br />Signature: E NGINieciti NCv . i <br />Technician I Cert #: Bruce N. Stewart I A31131 5249892 -UT Date: Deceltrber 26, 2007 <br />L, 2005 Walton tngmeenng, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.