Laserfiche WebLink
INDIVID' '_ TANK/LINE/LEAK DETECTOR -ST REPORT <br />TANKNOLOGY-NDE <br />TEST DATE: 08/20/97 WORK ORDER NUMBER: 2202245 <br />CLIENT: THE SOUTHLAND SITE: 7 -ELEVEN 19976 <br />TAt4 C I[VWIVI.A, <br />Tank ID:10x 3 Material: DW STEEL Bottom to top fill in inches: <br />143.0 <br />Product: REG UNLEAD Tank manifolded: NO Bottom to grade fill in inches: <br />153.0 <br />Capacity in gallons: 10,000 Vent manifolded: NO Fill pipe length in inches: <br />48.0 <br />Diameter in inches: 95.00 Vapor recovery manifolded: YES Fill pipe diameter in inches: <br />4.0 <br />Length in inches: 330 Impact Valves Operational: Y Stage I vapor recovery: <br />DUAL <br />Tank age (years): Overfill protection: YES Stage II vapor recovery: <br />ASSIST <br />Fuel pure rating: Overspill protection: YES Installed: <br />ATG <br />COMMENTS <br />TANK TEST RES,tiLTS Test MethbtY4uect <br />ESFUt�TSTSk,metl~koC)..v=' <br />x�LEICCITE+F�Ofiffi <br />...- _ _. <br />Start (in) End (in) <br />New/passed Failed/replaced New/passed <br />Failed/replaced <br />Dipped Water Level: 0.00 0.00 <br />L.D. #1 L.D. #1 L.D. #2 <br />L.D. #2 <br />Dipped Product Level: 40.00 40.00 <br />Make: VAPORLESS <br />Probe Water Level: 0.000 0.000 <br />Model: LD2000 <br />Ingress Detected: Water N Bubble N UllageN <br />S/N; 57787 <br />Test time: 12:02-13:52 <br />Open time in sec: 5.00 <br />VacuTect Test Type: Multiple <br />Holding psi: 45 <br />VacuTect Probe Entry Point: Fill <br />Resiliancy cc: <br />Pressure Set Point: -1.00 <br />Test leak rate ml/m: 189.0 <br />Tank water level in inches: 0.00 <br />Metering psi: 11 <br />Water table depth in inches: <br />Calib. leak in gph: 3.00 <br />Determined by (method): <br />Results: PASS <br />Result: PASS <br />COMMENTS <br />COMMENTS <br />mag probe <br />LINE TES �EStl T5 _; � , �' e # �Ln � <br />LINE= ,h�,� �,���...' �.y " ���.�_ �.8 �a�.w�t � ��.... ,..�.� C <br />D <br />Material: ENVIROFLEx <br />Diameter (in): 2.0 <br />Length (ft): 45.0 <br />Test psi: 50 <br />Bleedback cc: 0 <br />Test time (min): 30 <br />Test 1: Start time: 12 :3 0 <br />Finish psi: so <br />Vol change cc: -6 <br />Test 2: Start time: 12:40 <br />Finish psi: 50 <br />Vol change cc: 0 <br />Test 3: Start time: 12:50 <br />Finish psi: 50 <br />Vol change cc: 0 <br />Final gph: -0.003 <br />Result: PASS <br />Pump type PRESSURE <br />COMMENTS Pump make: FE PETRO <br />8900 SHOAL CREEK, BUILDING 200, AUSTIN, TEXAS 78757 (512) 451-6334 Draft 08/26/97 12:36 MSHAW <br />