Laserfiche WebLink
UNDERGROUND STORAGE TANK MONITORING PROGRAM <br />I. WRITTEN MONITORING PROCEDURES <br />1. Site Name: 7 -Eleven Facility No. 19976 <br />2. Site Address: 1399 N. Main Street, Manteca, CA 95336 <br />Describe the frequency of performing the monitoring method. <br />All Southland tanks, both single-wall and double-wall, are equipped with automatic tank gauges <br />(ATGs). The ATGs monitor the system constantly and test the tanks monthly to obtain a valid <br />monthly test (tank capacity between 50-90% full, 4 -hour wait time between deliveries and 6 -hour <br />test time). The piping systems (single-wall and double-wall) are monitored constantly by <br />mechanical pressure gauges. Additionally, all Southland piping systems receive line tightness tests <br />annually. <br />4. What method and equipment will be used for performing the monitoring? <br />Quantitative monitoring will be used at all Southland sites. The ATGs test both types of tanks <br />monthly. The ATG system used by the Southland Corporation is the TIDEL EMS. The piping <br />systems are tested annually with line tightness tests and are constantly monitored with Red Jackets or <br />Vaporless LD 2000 which will shut off the piping if the pressure drops too low. <br />5. Describe the location(s) where the monitoring will be performed. <br />The Red Jackets or Vaporless LD 2000 are located in the turbin pit. The ATGs are located in the <br />tanks. <br />6. List the name(s) of the person(s) responsible for performing the monitoring and/or maintaining the <br />equipment. <br />The individual(s) responsible for monitoring the equipment is/are the store operator(s). The store <br />operator(s) for this store is/are Man jit & GuMal Grewal . The Southland Corporation is <br />responsible for maintaining the equipment. <br />7. Reporting format: The TIDEL EMS unit keeps the results of leak tests in memory for 12 months. <br />This information can be printed by following the instructions on the unit. <br />8. State the preventive maintenance schedule for the monitoring equipment. Note: The maintenance <br />schedule shall be in accordance with the manufacturer's instructions. <br />Equipment repairs and replacement will be performed as needed. Additionally, in accordance with <br />the manufacturer's instructions, the monitoring equipment will be tested annually to certify that it is <br />functioning properly. <br />9. Describe the training needed for the operation of both the tank system and the monitoring equipment. <br />Training is provided for new employees. Training refreshers are offered as needed. The operations <br />manual for the equipment was provided to the store operator when the equipment was installed. <br />Training also includes emergency procedures and spill clean-up. <br />