Laserfiche WebLink
I� <br /> Table 2 <br /> GROUNDWATER ANALYTICAL RESULTS AND MONITORING DATA <br /> CHEVRON SERVICE STATION NO 9-0959 <br /> 1 D3 WEST 11th STREET TRACY CALIFORNIA <br /> WELL I D / ETHYL_ <br /> ELEVATION BENZENE TOLUENE BENZENE XYLENES TPH--G DTW SPT WTE <br /> OC DATE b b b b b feet fee! fee4 <br /> MW-1 <br /> 98 05 12/14/92 NO 16 6 5 18 2,4DO 1101 000 8704 <br /> MW-2 <br /> 711 12/14/512 ND 15 46 12 910 985 000 8726 <br /> MW-3 <br /> 9822 12114M ND ND ND ND ND 10 89 0 DO 67 33 <br /> EXPLANATION <br /> All elevations are given in feet and are surveyed relative to arbitrary <br /> datum of 10D feet on top of hydrant across Adams Street <br /> TOC=Top of casing <br /> TPH—G = Total Petrcieum Hydrocarbons—as—Gasoline <br /> DTW=Depth to water <br /> SFT=Separate—phase petroleum hydrocarbon thickness <br /> WTE=Water tabie elevation <br /> ppb = parts per billion <br /> ND Not detected at or above the rrurrmum quanfibation Itm t <br /> Note See kiboratory reports for rrurymurri uw*tabon limits <br />• <br /> i <br /> GROUNDWATER <br /> TECHNOLOG} <br />