Laserfiche WebLink
RECEM.' ' ""'"'' Appendix VI <br />1 � 'MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Cha EM <br />e I�t�i� _AL. Jety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br />This form must be used to do4u1n t1np, "VKt',( @ng of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control 'panel by the technician who performs the work. A copy of this form must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. <br />General Information <br />Facility <br />KI.—WATERLOO SHELL <br />Site <br />Aririracc• 4315 E. WATRERLOO RD <br />Facility Contact <br />Percnn <br />Make/Model of Monitoring System: <br />VEEDER ROOT TLS -350 <br />Bldg. No.: <br />City: STOCKTON <br />Contact Phone No.: <br />B. Inventory of Equipment Tested/Certified <br />Check the aoarooriate boxes to indicate specific eauioment inspected/serviced: <br />zip: 95205 R <br />Date of Testing/Servicing: 10/4/2012 <br />Tank ID: 87 <br />Tank Size: <br />Tank ID: 91 Tank Size: <br />® In -Tank Gauging Probe. <br />Model: MAG I <br />® In -Tank Gauging Probe, <br />Model: MAG 1 <br />® Annular Space or Vault Sensor. <br />Model: 302 <br />® Annular Space or Vault Sensor. <br />Model: 302 <br />® Piping Sump / Trench Sensor(s). <br />Model. 208 <br />® Piping Sump / Trench Sensor(s). <br />Model: 208 <br />® Fill Sump Sensor(s). <br />Model: 208 <br />® Fill Sump Sensor(s). <br />Model: 208 <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />® Electronic Line Leak Detector. <br />Model: PLL.D <br />® Electronic Line Leak Detector. <br />Model: PLLD <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: <br />Tank Size: <br />Tank ID: <br />Tank Size: <br />❑ In -Tank Gauging Probe. <br />Model: <br />❑ In -Tank Gauging Probe. Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />e <br />❑ Electronic Line Leak Detector. <br />Model: <br />C1 Electronic Line Leak Detector. <br />Model: <br />Cl Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 1 & 2 <br />Dispenser ID: 3 & 4 <br />® Dispenser Containment Sensor(s). <br />Model: 208 <br />® Dispenser Containment Sensor(s). <br />Model: 208 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5 & 6 <br />Dispenser ID: 7 & 8 <br />® Dispenser Containment Sensor(s). <br />Model: 208 <br />® Dispenser Containment Sensor(s). <br />Model: 208 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />Q Dispenser containment Float(s) and Chain's). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />"It the tacility contains more tanks or dispensers, copy this form. Include Information for every tank and dispenser at the tacility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): ® System set-up ® Alarm history report <br />Technician Name (print): ZANE NIMMO Signature: <br />Certification No.: A28446 _ License No: 04-1676 <br />Testing Company Name: AFFORDA-TEST Phone No. (209) 744-0113 <br />Testing Company Address: 4162 nSTREET GALT, CA 95632 Date of Testing/Servicing: 10/4/12 <br />Monitoring System Certification Page 1 of 4 2/21/07 <br />