My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4315
>
2300 - Underground Storage Tank Program
>
PR0231760
>
COMPLIANCE INFO 2010 - 2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2019 4:52:21 PM
Creation date
8/19/2019 4:16:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2013
RECORD_ID
PR0231760
PE
2351
FACILITY_ID
FA0003831
FACILITY_NAME
WATERLOO FOODMART
STREET_NUMBER
4315
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215-2305
APN
08710034
CURRENT_STATUS
01
SITE_LOCATION
4315 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
320
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd/unitiii.html <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Facility Inspection <br />Name Waterloo Shell address 4315 E Waterloo Road Date Oct 4, 2011 <br />VIOLATIONS <br /># <br />C1 <br />C2 M <br />Code Section <br />HSC = CA Health and Safety Code, CFR = Code of Federal Regulations <br />C1 = Class 1 violation, C2 = Class 2 violation, M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M1) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M1) <br />Other Violations <br />999 Other: See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to comply) <br />Routine and Monitoring System Certification UST inspection <br />201. The 2010 monitoring system certification results were not found on site. These records shall be <br />kept on site for at least 3 years. The inspector provided a copy of the above document to the operator <br />during the inspection. <br />202. An approved copy of the UST monitoring plan was not found on site. A copy of this plan shall be <br />retained on site at all times. The inspector provided a copy of the above document to the operator <br />during the inspection. <br />405. The L2 - 91 octane fill sump liquid sensor remained in alarm after testing and requires <br />replacement. The continuous monitoring system shall be maintained to detect the entry of the liquid or <br />vapor phase of the hazardous substance stored in the primary containment into the secondary <br />containment and to detect water intrusion into the secondary containment. Correct immediately by <br />having a properly licensed, trained, and certified contractor replace the failed component with a <br />functional component (LG 113-x listed, if applicable) and obtain a permit within one business day from <br />the EHD. If the failed component can't be replaced immediately, there is a possibility that the 91 octane <br />portion of the UST system may be red tagged to prevent fuel inputs. <br />Notes <br />1. Complete and submit a copy of the Return to Compliance Certification form with a statement of how <br />each violation was corrected, including supporting documentation, by November 4, 2011. <br />2. The emergency stop on the south side outside wall of the store did not turn off the fuel pumps when <br />tested. The inspector referred this test failure to Lt. Frank Ramirez of Waterloo - Morada Fire District at <br />931-3107. Waterloo-Morada Fire District has enforcement jurisdiction over the emergency stop device. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />
The URL can be used to link to this page
Your browser does not support the video tag.