COMPLIANCE INFO 2010 - 2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4315
>
2300 - Underground Storage Tank Program
>
PR0231760
>
COMPLIANCE INFO 2010 - 2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2019 4:52:21 PM
Creation date
8/19/2019 4:16:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2013
RECORD_ID
PR0231760
PE
2351
FACILITY_ID
FA0003831
FACILITY_NAME
WATERLOO FOODMART
STREET_NUMBER
4315
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215-2305
APN
08710034
CURRENT_STATUS
01
SITE_LOCATION
4315 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
320
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sicaov.org/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility Waterloo Foodmart Facility 4315 E Waterloo Road Stockton Inspection Oct 2, 2013 <br /> Name: Address: � Date: <br /> VIOLATIONS <br /> # C1 C2 M Code SCCtion HSC=CA Health and Safety Code;CFR=Code of Federal Regulations <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) (M1) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (Mi) <br /> Other Violations <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Routine and Monitoring System Certification UST inspection <br /> 104. Financial responsibility documents were obtained from the facility today. These financial <br /> responsibility documents are incomplete. Current financial responsibility documents are required to be <br /> submitted annually. Immediately submit a corrected copy of the financial responsibility documents to the <br /> San Joaquin County Environmental Health Department (EHD). Alternatively, log into CERS, upload the <br /> required information, and submit for review by the EHD. Complete by November 2, 2013. <br /> 201. Complete alarm logs were not found on site. The following alarms were not documented in the <br /> alarm log by the facility manager or clerk: S2 - vapor line - 7/11/13, 5/29/13 - communication alarm; <br /> S3 - 91 line - 9/6/13, 6/17/13 - no vacuum alarm; S3 - 91 line - 7/3/13 - communication alarm., S4 - <br /> vent lines - 8/28/13 - communication alarm. Document all L, Q and S alarms in the alarm log. Include <br /> the date of the alarm, identification of the alarm sensor, and the action taken to resolve the alarm. <br /> Complete a corrective action statement and submit to the EHD by November 2, 2013. <br /> 204. The designated operator failed to document all the alarms from the attached alarm history on the <br /> designated operator monthly inspection reports and failed to check that they were responded to <br /> appropriately. The missing alarms include: S1 - 87 line - 5/13/13 - high liquid alarm, S1 - 87 line - <br /> 5/20/13 - no vacuum alarm, S2 - vapor line - 7/11/13, 5/29/13 - communication alarm; S3 - 91 line - <br /> 9/6/13, 6/17/13 - no vacuum alarm; S3 - 91 line - 7/3/13 - communication alarm., S4 - vent lines - <br /> 8/28/13 - communication alarm, L18 - vent annular sensor - 10/21/12, 10/13/12, 10/4/12 - fuel alarm. <br /> During the monthly inspection, the designated operator shall review the alarm history for the previous <br /> month, check that each alarm was documented and responded to appropriately, and attach a copy of <br /> the alarm history with documentation taken in response to any alarms to the monthly report. Ensure that <br /> designated operators performing monthly inspections at this facility are including all of the required <br /> information on the reports. Complete a corrective action statement and submit to the EHD by November <br /> 2, 2013. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Insp / Received By: Title: <br /> El-161&0 Rev 04/19/12 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.