My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2017 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4315
>
2300 - Underground Storage Tank Program
>
PR0231760
>
COMPLIANCE INFO 2017 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/21/2019 11:07:05 AM
Creation date
8/21/2019 9:40:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017 - 2018
RECORD_ID
PR0231760
PE
2351
FACILITY_ID
FA0003831
FACILITY_NAME
WATERLOO FOODMART
STREET_NUMBER
4315
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215-2305
APN
08710034
CURRENT_STATUS
01
SITE_LOCATION
4315 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
304
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQuiN <br />—COUNTY -- <br />.dit-a- 'r <br />:, � CN-. `1 Greatness grows here. <br />May 31, 2018 <br />Elite IV Contractors <br />Attn: Megan Mitchell <br />2535 Wigwam Dr. <br />Stockton, CA 95205 <br />Re: Waterloo Food Mart <br />4315 E Waterloo Rd <br />Stockton, CA 95215 <br />Environme, inial Health Department <br />Linda Turkatte, RENS, Director <br />Kasey Foley, REHS, Assistant Director <br />PROGRAM COORDINATORS <br />Robert McClellon, REHS <br />Jeff Carruesco, REHS, RDI <br />Rodney Estrada, REHS <br />Willy Ng, REHS <br />Muniappa Naidu, REHS <br />AMENDED <br />FILECOPY SR0078796 <br />The San Joaquin County Environmental Health Department (EHD) has completed the review of the <br />amended application for a permit to remove and replace all four dispensers and under dispenser <br />containers (UDCs), install new pipe entry fittings, plumb product and vapor piping into each UDC, <br />remove existing interior vent box to remove and replace electrical boots with diversified repair boots, <br />and install a new communication test port on the 87 submersible turbine pump (STP) sump on the <br />underground storage tank (UST) system at the above noted address. The permit has been approved <br />with the following conditions: <br />Contact the local fire department and the San Joaquin Valley Air Pollution Control District and <br />local city building department for any applicable permits and requirements. <br />2. Any changes in information and scope of work must be submitted to EHD for approval prior to <br />commencing work. All new addenda supersede the previous ones. <br />3. Contact Elianna Florido at (209) 468-0343 to arrange the following inspection appointments (a <br />48-hour notice is required for inspection appointments). Please be aware that inspections for <br />emergency work must be scheduled within five days of permit approval. <br />a. Witness soil sampling from under each removed UDC. If primary piping is removed outside <br />of UDC or sumps, additional soil samples will be required based on field observations and <br />as outlined in the sampling protocol. Analytical results to be provided to Environmental <br />Health Department. The San Joaquin County Sampling Protocol For Routine <br />Piping/Dispenser Removal /Replacement shall be followed. <br />b. Primary piping soap test on the installed UDC product piping and penetrations: One-hour <br />pneumatic pressure test at 110% of operating pressure, or 40 psi, whichever is greater. <br />c. Secondary piping slope (at 1/8 inch per foot or greater) to a containment sump with an <br />audible/visual alarm <br />d. Secondary piping soap test on the installed UDC piping and penetrations: One-hour <br />pressure test at the manufacturer's recommended specification. If there are no <br />manufacturer's guidelines, test shall be performed using an applicable method specified in <br />an industry code or engineering standard, after backfill and concrete is poured. <br />e. Visual inspection of the piping within the dispensers. <br />f. Verification of the dispenser footprints contained by the under dispenser containment <br />sumps (UDCs), any potential leaks from piping and fuel filters must drain into UDCs. <br />g. Verification of communication for all newly installed vacuum, pressure, or hydrostatic (VPH) <br />components. <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.