FACILITY_NAME
WATERLOO FOODMART
STREET_NUMBER
4315
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215-2305
APN
08710034
CURRENT_STATUS
01
SITE_LOCATION
4315 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
304
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br />20) Smith Bulletin 132102 May 1, 2006 JUL 0 3 2018 <br />21) Ameron PSX-20 Adhesive Kit - Bondstrand Product Data FP698B (10/04) <br />22) RPM Technology Petrol Seal Weight Loss and Flexibility ENVIRONMENTAL <br />23) RPM Technology Petrol Seal Swell Test Results HE,AI_Tu DEPARTMENT <br />24) RPM Technology Petrol Seal Test Reports with Methods <br />25) RPM Technology Petrol Seal Summary Test Report Fuel Exposure <br />This system provides a permanent retrofit solution to replace from the inside of a containment sump, <br />a new, suspect or failing Blue Line Technologies Kwik -Fit flexible penetration fitting which is used <br />to make a seal between the fiberglass wall and steel conduit or fiberglass piping. This product <br />maintains the integrity of the interstice of the double wall containment sump by sealing the <br />secondary wall (outer) and the primary wall (inner) to the pipe line that passes through them. I have <br />noted that standard models of the D-BLR-S and D -INR -S are available that are each tailored to each <br />type of pipe but also that oversized or custom made components are availalbe should they be <br />required based on a specific application or site conditions. For the purposes of this review, I have: <br />1) Reviewed the construction and installation procedures for both the double wall F -Series <br />full body and the split Retrofit -SD -AB Series fiberglass retrofit fittings for fiberglass <br />pipe and conduit. <br />2) Reviewed the construction and installation procedures for the double wall F -Series <br />fiberglass split retrofit D-BLR-S and D -INR -S Series fittings for conduit. <br />3) Reviewed materials used to construct the secondary containment system for sufficient <br />thickness, density and corrosion resistance to prevent structural weakening or damage to <br />the secondary containment system as a result of contact with hazardous substances <br />contained in California fuels or their additives. <br />Upon review of the manufacturing procedures, employment of the materials used in the fabrication <br />of the F -Series D-BLR-S and D -INR -S fitting product lines and the manufacturer's installation <br />guidelines, it is my conclusion that sound design and engineering of this product for use with <br />fiberglass double wall containment structures and aforementioned conduit and fiberglass piping will <br />meet or exceed the secondary containment requirements as concerns corrosion resistance and <br />material compatibility of all motor vehicle fuels, alternative fuels or their additives currently used by <br />petroleum marketers today. 1 approve the above engineering specifications for the Bravo <br />F -Series D-BLR-S and D -INR -S Series retolit entry fittings. <br />Please contact me with any questions at 323-888-4136. AafESSIO <br />K. Mbr <br />Sinc,erely, <br />a N0.3027 <br />Don K. Muka�•' <br />Mechanical Engineer <br />OF CAI.t� <br />3RP-FS-D-BLR-S PAGE 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.