Laserfiche WebLink
OPW 10 Series Emergency Shut -Off Valves <br />Ordering Specifications <br />Female Threaded Top (Outlet) Connection Valves <br />Body Size <br />Model # Connection Threads Poppet Configuration Application Replacement Top <br />in. cm <br />1OBF-5725 1'/1 4 NPT Single Pressure 1ORFT-5750 <br />1OBFP-5726 1'/2 4 NPT Double Pressure 1OFTP-5701 <br />IORF-2001 <br />2 5 <br />NPT <br />Single <br />Pressure <br />1ORFT-5742 <br />1ORFP-2002 <br />2 5 <br />NPT <br />Double <br />Pressure <br />1ORFTP-5752 <br />Male Threaded -Top (Outlet) Connection Valves <br />Body Size <br />Model # Connection Threads <br />in. kg <br />Poppet Configuration <br />Application <br />Replacement Top <br />10BM-5825 <br />11/7 4 <br />NPT <br />Single <br />Pressure <br />1ORMT-5850 <br />IOBHMP-5830 <br />1'h 4 <br />NPT <br />Double <br />Pressure <br />1ORMTP-5851 <br />1OSBHMP-5830 <br />1'/2 4 <br />NPT <br />Double <br />Suction <br />1OSHMTP-5811 <br />1ORM-2003 <br />2 5 <br />NPT <br />Single <br />Pressure <br />1ORMT-5842 <br />1ORMP-2004 <br />2 5 <br />NPT <br />Double <br />Pressure <br />1ORMTP-5852 <br />Union -Top (Outlet) Connection Valves <br />Body Size <br />Model # Connection <br />in. kg <br />Threads <br />Poppet Configuration <br />Application <br />Replacement Top <br />1OBU-5925 <br />11k 4 <br />NPT <br />Single <br />Pressure <br />1ORUTC-5975 <br />1OBUP-5926 <br />1111 4 <br />NPT <br />Double <br />Pressure <br />1OUTCP-5901 <br />10SBUP-5926 <br />1'/2 4 <br />NPT <br />Double <br />Suction <br />10SUTCP-5911 <br />1ORU-2005 <br />2 5 <br />NPT <br />Single <br />Pressure <br />1ORUTC-5962 <br />1ORUP-2006 <br />2 5 <br />NPT <br />Double <br />Pressure <br />1ORUTCP-5972 <br />NOTE: All BSPP Thread Shear Valves must be ordered through DPW's Europe or Asia office. <br />IMPORTANT NOTICE: <br />When mounting the DPW 10 Series Emergency Shut-off Valves, the anchoring system employed must withstand a force greater than 650 ft. pounds per valve. <br />NFPA Code 30A, Automotive and Marine Service Station Code, requires that the automatic closing feature of emergency shut-off valves be checked at least <br />once per year by manually tripping the hold -open linkage. DPW recommends the use of Flexworks Stabilizer Bar Support System for proper mounting <br />of 10 Series Valves. <br />NOTICE: <br />As per NFPA 30A, electrical supply to the submersible pump must always be disconnected before servicing meters, dispensers or emergency shut-off valves. <br />120 D <br />