Laserfiche WebLink
"\ S AN 10A0UIN <br />COUNTY <br />��tiFoa� Greatness grows here. <br />July 19, 2018 <br />MEGAN MITCHELL <br />ELITE IV CONTRACTORS <br />2535 WIGWAM DR <br />STOCKTON, CA 95205 <br />Re: WATERLOO FOODMART <br />4315 E WATERLOO RD <br />STOCKTON, CA 95215-2305 <br />Environmental Health Department <br />FILE COPY <br />Linda Turkatte, REHS, Director <br />Kasey Foley, REHS, Assistant Director <br />PROGRAM COORDINATORS <br />Robert McClellon, REHS <br />Jeff Carruesco, REHS, RDI <br />Rodney Estrada, REHS <br />Willy Ng, REHS <br />Muniappa Naidu, REHS <br />SR0079401 <br />The San Joaquin County Environmental Health Department (EHD) has completed the review of the <br />application for a permit to replace the 420 vent annular sensor on the underground storage tank (UST) <br />system at the above noted address. This work was completed on May 24, 2018. The permit has been <br />approved with the following conditions: <br />1. Contact the local fire department and the San Joaquin Valley Air Pollution Control District for any <br />applicable permits and requirements. <br />2. Any changes in information and scope of work must be submitted to EHD for approval prior to <br />commencing work. All new addenda supersede the previous ones. <br />3. Contact Stacy Rivera at (209) 468-3440 to arrange the following appointments (a 48-hour notice is <br />required for inspection appointments). Please be aware that inspections for emergency work must be <br />scheduled within five days of permit approval. <br />• Sensor functionality: Functionality of the monitoring system must be verified to ensure that <br />monitoring has been restored to meet the requirements of Title 23 California Code of Regulations <br />and the Health & Safety Code. If it is determined that a cold start is necessary, a copy of the <br />alarm history shall be printed prior to performing the "cold start" of the monitoring system and <br />made available at the time of EHD inspection. <br />4. If concrete will be broken near the tank, a secondary containment test must be performed on the <br />tank once concrete is poured in accordance with the manufacturer's guidelines. <br />5. Any individual performing the work of a service technician must meet the following qualifications: <br />a. Possess or be employed by a person who possesses one of several permissible valid, current <br />contractor's licenses issued by the Contractors State License Board (may be issued to the <br />installation company), or a Tank Tester's license issued to the individual by the State Water <br />Board, and <br />b. Possess or work under the direct and personal supervision of an individual physically present at <br />the work site who possesses a valid, current California UST Service Technician certificate issued <br />by the International Code Council (ICC), and <br />c. Possesses a valid, current certificate of training from the manufacturer(s) of the component(s) <br />being tested, repaired, or serviced. <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />