My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2017 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4315
>
2300 - Underground Storage Tank Program
>
PR0231760
>
COMPLIANCE INFO 2017 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/21/2019 11:07:05 AM
Creation date
8/21/2019 9:40:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017 - 2018
RECORD_ID
PR0231760
PE
2351
FACILITY_ID
FA0003831
FACILITY_NAME
WATERLOO FOODMART
STREET_NUMBER
4315
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215-2305
APN
08710034
CURRENT_STATUS
01
SITE_LOCATION
4315 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
304
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> WATERLOO FOODMART 4315 E WATERLOO RD, STOCKTON April 10, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 304 HSC 25290.1(d) Monitoring system not maintained to detect entry into secondary containment (after Jul 2004). <br /> The 91 product fill sump 208 sensor failed when tested. The continuous monitoring system shall be maintained to <br /> detect the entry of the liquid or vapor phase of the hazardous substance stored in the primary containment into the <br /> secondary containment and to detect water intrusion into the secondary containment. The service technician turned <br /> the sensor upside down prior to retesting it upright vertically in water. The 208 sensor sensor passed the second <br /> time. <br /> This was corrected on site. <br /> This is a minor violation. <br /> 305 HSC 25290.1(e) VPH monitoring of the interstitial spaces of the UST system is not maintained. <br /> Communication in the 87 and 91 product submersible turbine pump (STP) and fill sumps of the vacuum pressure <br /> hydrostatic (VPH) system were not tested during the inspection on 4/10/17. The interstitial space of the <br /> underground storage tank system shall be maintained as designed under constant vacuum such that a breach in <br /> the primary or secondary containment is detected before the hazardous substance is released into the environment. <br /> Immediately contact a properly licensed, trained and certified contractor to install and test communication of the <br /> VPH system components under permit and inspection by the environmental health department. <br /> This is a repeat violation, Class II. <br /> 316 HSC 25290.1(c3), 25290.2(c3) Secondary containment not constructed to prevent water intrusion (after Jul 2003). <br /> An eighth of a cup of liquid was found in the 91-product fill sump. Moisture was found in the 87 and 91-product <br /> submersible turbine pump (STP) sumps. Secondary containment shall be constructed to prevent any water <br /> intrusion into the system by precipitation, infiltration, or surface runoff. The service technician removed the liquid and <br /> moister from the 91-product fill sump and the 81-and 91-product STP sumps. <br /> This was corrected on site. <br /> This is a repeat violation, Class Il. <br /> 319 CCR 2635(b) No spill bucket, failed to contain five gallons, or failed to provide a means to keep it empty. <br /> The 87-product spill bucket failed the one hour hydrostatic test. The service technician made no corrections and <br /> retested the 87-product spill bucket. The 87-product spill bucket passed after being retested. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by May 10, 2017. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br /> FA0003831 PR0231760 SCO01 04/10/2017 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 5 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.