Laserfiche WebLink
10/19/95 <br /> Unit running on arrival . Adjust unit System set at Oo air <br /> (, dilute. <br /> I The VOC emissions have never exceeded the 52 lb/day emission <br /> limit for the site No evidence of Tetrachloroethene (PCE) was <br /> found during examination of the chromatograms of the samples <br /> taken to the WEGE laboratory <br /> VAPOR SAMPLING <br /> COLLECTING LABORATORY SAMPLES <br /> Influent Sample <br /> The influent sample is obtained from a sample port located, after <br /> the system vacuum pump and before the REMOX Unit . Sterile poly <br /> tubing is then used to attach a 1 liter tedlar bag, fitted with a <br /> special septum "valve" and tubing bib, to the sample port The <br /> sample port is on the pressure side of the pump and therefore the <br /> bag will fill without need of a pump Once the tedlar bag is <br /> filled, its valve is closed and locked, the appropriate label is <br /> placed on the tedlar bag <br /> Effluent Sample <br /> A sample port for the effluent is located in the exhaust stack of <br /> the Remox system The flow pressure from the exhaust is great <br /> enough to fill a tedlar bag Sterile poly tubing is fitted to <br /> the exhaust port and the tedlar bag Then the sample valve of <br /> the tedlar bag is opened and the bag is filled with the sample <br /> Once the tedlar bag is full, the valve is closed and locked, the <br /> sample port closed, and the appropriate label is placed on the <br /> bag <br /> The labels for both the influent and effluent tedlar bag samples <br /> show the date, time, sample ID# and analyses to be run <br /> Both the influent and effluent tedlar bag samples are then placed <br /> within a cooler, on ice, and are hand delivered to WEGE' s <br /> laboratory that same day <br /> The vapor sample is then infected into an FID (Flame Ionizing <br /> Detector) chromatograph and the resulting chromatogram compared <br /> to standard chromatograms of known TFH (Total Fuel Hydrocarbons, <br /> gasoline) and BTEX (benzene, toluene, ethylbenzene, and xylenes) <br /> concentrations . A dual chromatograph comparison is also run <br /> (Photovac 10S50) to evaluate BTEX, TCE, PCE, and DCE <br /> FLOW RATES <br /> Flow rates are measured at the site by using orifice plates . A <br /> one inch orifice is placed in line for each well and a three inch <br /> 2 Regal 503 , 1.0/24/95 <br />