Laserfiche WebLink
13. Control Device (Information should include, but not be limited to, description, manufacturer, model#, power rating, and <br /> the manufacturer's guaranteed hydrocarbon control efficiency) <br /> 2 - 110 gallon vapor scrub carbon units in series. Cameron Yakima 25[7190, maximum flow <br /> 125 cfm, maximum pressure 10 psig, maximum temp 125°F, carbon capacity 400 pounds <br /> absorption = 30%. <br /> 14. Other Equipment; (Should include the manufacturer, model number, power rating, and flow rating. The list should <br /> include, but not be hinted to, air strippers, fans, and pumps) <br /> Blowers - 2 Regenerative blowers in series <br /> Rofron DR 505, 2HP,1P 115/230, explosion proof <br /> maximum pressure 68 inches water <br /> maximum suction 62 inches water <br /> maximum flow pressure 73 scfm <br /> minimum flow - suction 58 scfm <br /> maximum operating temp 140°C <br /> 15. Type Of Supplemental Fuel And Maximum Daily Usage N/A <br /> 16. Maximum Length Of Project: 2 years <br /> 17. Stack Gas Temperature 1 20°F <br /> 18. Stant C'rac V0.1nr1ty. 'i-A 4 0 i+t/,,, .n i%t" <br /> 19. Stack Height&Diameter. 1 Oft x 2 inch <br />.ease Submit The Following: <br /> 1.. A sketch of the equipment configuration. <br /> 2. Copies of lab results and equipment data sheets. <br /> 3. Completely fill out this form, all information submitted may become a permit condition. Incomplete <br /> forms will be returned. <br />